Pacific Research Solutions RI-300e User Manual Page 152 S-Cmd Command Description and Data Format Read Back Syntax Command Syntax Factory Setting Stored Location
27 Tone Remote Decode Set up
Item 0 = Decode tolerance
Data = 1-20 in 0.5 percent increments
Item 1-8 = Decode frequencies,
Data = 0 (Disable), 650-3000 (Hz)
27 [Item] 27 [Item] [Data] Item 0
4 (2%)
Item 1-8
2175 Hz
2050 Hz
1950 Hz
1850 Hz
1750 Hz
1650 Hz
1550 Hz
1450 Hz
RAM
EEPROM
28 Tone Remote Mode and Notch Filter Control
Item 0 = Tone remote mode
Data 0 = Disable, 1 = RX decode, 2 = AUX decode
3 = TEL decode, 4 = RX tone remote pass,
5 = RX tone remote mute, 6 = AUX tone remote pass,
7 = AUX tone remote mute, 8 = TEL tone remote pass
9 = TEL tone remote mute
Item 1 = Decoder response
Data 0-14 = 36-576 mS in 36 mS increments
Item 2 = No tone timer
Data 0-7 = 10-150 mS in 20 mS increments
Item 3 = Notch filter select
Data 0 = Disable, 1 = Repeater, 2 = Aux, 3 = Tel
Item 4 = Tone remote PTT encode mode
Data 0 = Disable, 1 = TX encode, 2 = TX invert,
3 = Telephone encode, 3 = Telephone invert
Item 5 = Tone burst timer
Data 1-99 = 100mS to 9900mS in 100mS increments
Item 6 = Tone Encode,
Data 0 = No tone, 1-8 = Tone number 1 through 8
28 [Item] 28 [Item] [Data] Item 0
0 (Disable)
Item 1
2 (72mS)
Item 2
3 (70mS)
Item 3
0 (Disable)
Item 4
0 (Disable)
Item 5
2 (200mS)
Item 6
N/A
RAM
EEPROM
29 Reset Message Buffer
Buffer 0 = Tone Generator, 1 = Speech
Mode 0 = Reset current message, 1 = Clear all messages
N/A 29 [Buffer] [Mode] N/A N/A
30 Speech message data
Speech Data = See speech data table 30 *
[Speech
Data]
30 [Speech Data] N/A N/A
31 Tone generator data
Tone Data = See tone data table 31 *
[Tone Data] 31 [Tone Data] N/A N/A
32 Message and Event macro triggers.
Msg Trig 01 = Clock Reset Courtesy,
02 = Weak signal Courtesy,
03 = Clock not set Courtesy,
04 = Un-Lock Courtesy, 05 = Hourly message,
06 = Cleanup ID, 07 = Post time-out, 08 = Pre time-out,
09 = Acknowledgment, 10 = Error, 11 = ID,
12 = Ring Message, 13 = AP answer,
14 = AP Acknowledgment, 15 = AP Error,
16 = AP Ring,
Event Trig 17 = Power on macro,
18 = Telephone hang-up, 19 = Telephone auto answer
Line = 1 - 999 and 0 = no message
32
[Msg/Event
Trig]
32 [Msg/Event Trig]
[Line] See
Table RAM
EEPROM
33 DVR Message edit
Function 0 = Delete, 1 = Record, 2 = Play, 3 = Time,
9 = DVR Select
Msg 1-50, 0 = Stop play/record or total time
DVR Sel 0 = No DVR, 1 = 120S, 2 - 240S, 3 = 480S
N/A 33 [Function] [Msg] 90 EEPROM