Pacific Research Solutions RI-300e User Manual
Page 30
The following is a list of all S-Commands associated with the tone squelch decode and encode.
S-Command Description
01 System Mode (Repeater tone squelch decode enable)
14 User and System Command tone panel decode enable
20 Tone panel decode set up
21 Tone panel master and cross encode set up
22 Tone panel encode mode
23 External source tone panel encode set up
24 CTCSS and DCS encode level control
25 DCS TX/RX data polarity control
26 CTCSS/DCS decode total air-time
34 Auxiliary output tone panel enable
49 Dial Click command set up
72 Telephone tone panel decode enable
EVENT SCHEDULER (RI-300, Version 2)
The RI-300 has a time of day scheduler which can be used to automatically execute commands at pre-programmed times of the
day. For the scheduler to work, the system time clock must be set, using S-Command 43. See the programming section for
more details. The scheduler uses the system clock to determine when to execute a command. Because the system clock does
not have a battery backup, it must be reset each time the power is restored to the repeater controller. You can also enable a
courtesy message trigger that will let you know when the time clock needs to be reset.
Enable the “CLOCK NOT SET” Courtesy Message
1. Unlock the controller, send the password and un-key, you will hear a function complete.
2. Change the clock not set trigger from the standard courtesy message to the CW “RST” message, send “32 0 3 21” and un-
key, you will hear a function complete.
3. When you are done, send “69 1” to lock the controller and save your changes. If needed, you can also send a “69 0” to
lock the controller and exit S-Command mode without saving changes.
4. You will now notice a new courtesy message.
Once the system time clock has been set and the schedulers have been set up the command will be automatically executed.
Sixteen individual schedulers are available. To set up the scheduler, use S-Command 44. See the programming section for
more details.
The RI-300 can also execute commands based on many other timed and internal events. See S-Commands 40 through 48 for
additional information on this subject.
EVENT SCHEDULER (RI-300e, Version 3)
The RI-300e has a time of day and date scheduler which can be used to automatically execute commands at pre-programmed
times of the day, week or year. For the scheduler to work, the system time clock must be correctly set, using S-Command 43.
See the programming section for more details. The scheduler uses the system clock to determine when to execute a command.
This system clock is a battery backed real time clock and will continue to keep time even when power is removed form the
controller.
Once the system time clock has been set and the schedulers have been set up the command will be automatically executed.
Thirty-two individual schedulers are available. To set up the scheduler, use S-Command 44. See the programming section for
more details.
The RI-300 can also execute commands based on many other timed and internal events. See S-Commands 40 through 48 for
additional information on this subject.