Viewfinder displays

Viewfinder lamp displays

1

REC

BATT

VTR

SAVE

2 3 4

The displays shown in the example are those of the AJ-VF10.

(For details on the viewfinder, refer to the operating instructions of the viewfinder available as an optional accessory.)

1REC (record) lamp

This lights up red during recording. It flashes when an error has occurred. For further details, refer to “Warning system” (page 38).

2 (irregular operation status warning) lamp

This lights up when the unit is placed in an irregular operation status for any of the items set to ON in the sub-menu <!LED>.

For details on selecting the items subject to the lamp display, refer to sub-menu <!LED> (page 37).

3BATT (battery) lamp

This starts flashing several minutes before the battery voltage drops to the level where the battery can no longer be used, and it remains lit when the battery can no longer be used. To prevent an interruption to operation, replace the battery before the battery becomes completely discharged. For further details, refer to “Warning system” (page 38).

4VTR SAVE (VTR power-saving) lamp

This lights up when the VTR SAVE/STBY switch is set to SAVE. It goes off during recording.

Viewfinder screen status displays

In addition to the images, messages indicating the unit’s settings and the operation mode appear on the viewfinder screen.

Also displayed are the centre marker and safety zone markers.

At the top, bottom and right edges of the screen are the items which have been set to ON using the sub-menu <MARKER/ZEBRA>, <VF DISPLAY 1/2> and <VF DISPLAY 2/2> screens or the switches relating to the viewfinder displays. When a setting has been changed or an adjustment is made, a message informing the user of the setting details, adjustment transition status and adjustment result is displayed for about 3 seconds.

For further details, refer to the items concerned on the sub-menu <MARKER/ZEBRA>, <VF DISPLAY 1/2>, <VF DISPLAY 2/2>, <!LED>, <CAMERA ID> and <TIME DATE> screens.

 

 

 

<

 

 

 

1

 

 

 

 

 

I

 

EX

TAPE NEAR END FLUO.

 

 

=

 

 

2iREC TCG 12:34:56:00

3

 

 

 

 

 

AWB+02

>

 

 

 

 

 

 

 

4

 

 

 

 

 

Z78

?

 

 

 

 

 

 

5

 

¢1¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢

32K.

@

 

 

 

 

 

 

 

 

¢

2¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢

ATW

A

 

 

7

 

 

 

 

 

F56.

B

6

SPOT

QUICK FOCUS

0dB

C

FL1

D

 

8

160/

 

LOW LIGHT

 

 

9D01-May-01 23:59:00 E

:

 

48K CH2CH1

=========

¢¢¢min

13.4V

 

 

 

 

 

 

 

 

 

 

 

 

 

;

 

 

 

G

H

 

 

 

F

Status displays on the viewfinder screen when the MODE CHECK switch is ON (normal)

 

 

 

 

 

 

 

 

 

 

EX

TAPE NEAR END FLUO.

 

 

 

 

TCG 12:34:56.00

 

 

SCENE F1:FLUO.

 

WHITE :A 3.6K

 

 

 

 

 

 

 

 

 

 

 

KNEE

:MANUAL

 

 

A.IRIS:BACK

 

GAIN

:0dB

 

 

GAMMA :NORMAL

 

FILTER:1

 

 

COLOUR:+10

 

SHUT

:OFF

 

 

SKIN :OFF

!¢¢¢¢¢¢¢¢¢¢¢¢ J D01-May-01 23:59:00

48K CH2CH1 ========= ¢¢¢min 13.4V

ENGLISH

<Note>

After the period set for the pause timer is exceeded during Rec Pause, or after 1 minute has passed during Pause (Still), the unit will automatically switch to SAVE mode and the lamp will light, regardless of the VTR SAVE/STBY switch position.

Status displays on the viewfinder screen when the MODE CHECK switch is ON (FULL AUTO)

 

 

 

 

 

 

 

 

EX

TAPE NEAR END

FULL

 

 

 

 

TCG 12:34:56.00

 

 

 

SCENE F1:FLUO.

FULL AUTO

FILTER:1

GAMMA :NORMAL

SKIN :OFF

!¢¢¢¢¢¢¢¢¢¢¢¢ J D01-May-01 23:59:00

48K CH2CH1 ========= ¢¢¢min 13.4V

16 (E)