Warning system

When an error or a problem is detected immediately after the power is turned on or while an operation is underway, the WARNING lamp and lamps inside the viewfinder serve to alert the user.

ENGLISH

SLACK

WARNING lamp

Flashes four times per second.

 

 

Tally lamp

Flashes four times per second.

 

 

Viewfinder

The SLACK display flashes.

 

 

Description of warning

Trouble has occurred in the motor, solenoid or

 

other mechanism.

 

 

VTR unit operation

The tape stops travelling. When solenoid

 

trouble has been detected, the power is turned

 

off.

 

 

Remedial action

Check the error code (see page 40) shown in

 

the viewfinder and consult your nearest service

 

centre.

 

 

REC WARNING

WARNING lamp

Flashes four times per second (for over 3

 

seconds during recording).

 

 

Tally lamp

Flashes four times per second (for over 3

 

seconds during recording).

 

 

Viewfinder

The REC WARNING display flashes (for over 3

 

seconds during recording).

 

 

Description of warning

A problem has occurred with the recording

 

control signals.

 

 

VTR unit operation

Recording continues but it may not be

 

performed properly while the warning is

 

displayed.

 

 

Remedial action

This problem has occurred with the control

 

signals inside the unit. Consult your nearest

 

service centre.

 

 

RF

WARNING lamp

Flashes four times per second (during

 

recording).

 

 

Tally lamp

Flashes four times per second (during

 

recording).

 

 

Viewfinder

The RF display flashes (during recording).

 

 

Description of warning

The video heads are clogged. This problem

 

occurs in the recording system.

 

 

VTR unit operation

The cleaning roller is actuated to clean the

 

heads (max. 3 seconds). Recording continues

 

but it may not be performed properly.

 

The warning display remains flashing up to the

 

REC/PAUSE mode. It goes out when the unit’s

 

mode is transferred from REC/PAUSE.

 

 

Remedial action

Clean the heads. If recording still cannot be

 

performed properly even after they have been

 

cleaned, turn off the unit’s power, and consult

 

your nearest service centre.

 

 

SERVO

WARNING lamp

Flashes four times per second (during recording

 

and playback).

 

 

Tally lamp

Flashes four times per second (during recording

 

and playback).

 

 

Viewfinder

The SERVO display flashes (during recording

 

and playback).

 

 

Description of warning

The servo is out of sync.

 

 

VTR unit operation

Operation continues but it may not be performed

 

properly.

 

 

Remedial action

Turn off the unit’s power, and consult your

 

dealer.

 

 

HUMID

WARNING lamp

Lights when condensation has been detected.

 

Flashes once a second from 10 minutes after

 

the condensation detection has been released

 

for a duration of 80 minutes.

 

 

Tally lamp

Flashes four times per second starting at the

 

time when the condensation was detected

 

until 10 minutes have elapsed after the

 

condensation detection was released.

 

The lamp turns off 10 minutes after the

 

condensation detection status is released.

 

 

Viewfinder

The HUMID display flashes starting at the time

 

when the condensation was detected until 90

 

minutes have elapsed after the condensation

 

detection was released.

 

 

Description of warning

Condensation has formed.

 

 

VTR unit operation

The recording operation continues but it will stop

 

if the tape sticks. For 80 minutes after the

 

condensation detection was released, the

 

operation which causes the drum to rotate is not

 

acknowledged.

 

 

Remedial action

Stop the tape travel, and turn off the unit’s

 

power. If the HUMID display fails to go out even

 

after the power has been turned back on, wait

 

until it goes out.

 

 

TAPE NEAR END

WARNING lamp

Flashes once per second (during recording).

 

 

Tally lamp

Flashes once per second (during recording).

 

 

Viewfinder

The remaining tape display flashes (in the EE

 

mode)

 

≥ = flashes for 3 seconds one minute before

 

the tape-end.

 

 

Description of warning

The tape is approaching its end (2 minutes

 

remain).

 

 

VTR unit operation

Operation continues.

 

 

Remedial action

Replace the cassette tape as necessary.

 

 

38 (E)

Page 39
Image 39
Panasonic AG-DVC 200E manual Slack, REC Warning, Servo, Humid, Tape Near END