Warning system
When an error or a problem is detected immediately after the power is turned on or while an operation is underway, the WARNING lamp and lamps inside the viewfinder serve to alert the user.
ENGLISH
∫ SLACK
WARNING lamp | Flashes four times per second. |
|
|
Tally lamp | Flashes four times per second. |
|
|
Viewfinder | The SLACK display flashes. |
|
|
Description of warning | Trouble has occurred in the motor, solenoid or |
| other mechanism. |
|
|
VTR unit operation | The tape stops travelling. When solenoid |
| trouble has been detected, the power is turned |
| off. |
|
|
Remedial action | Check the error code (see page 40) shown in |
| the viewfinder and consult your nearest service |
| centre. |
|
|
∫REC WARNING
WARNING lamp | Flashes four times per second (for over 3 |
| seconds during recording). |
|
|
Tally lamp | Flashes four times per second (for over 3 |
| seconds during recording). |
|
|
Viewfinder | The REC WARNING display flashes (for over 3 |
| seconds during recording). |
|
|
Description of warning | A problem has occurred with the recording |
| control signals. |
|
|
VTR unit operation | Recording continues but it may not be |
| performed properly while the warning is |
| displayed. |
|
|
Remedial action | This problem has occurred with the control |
| signals inside the unit. Consult your nearest |
| service centre. |
|
|
∫ RF
WARNING lamp | Flashes four times per second (during |
| recording). |
|
|
Tally lamp | Flashes four times per second (during |
| recording). |
|
|
Viewfinder | The RF display flashes (during recording). |
|
|
Description of warning | The video heads are clogged. This problem |
| occurs in the recording system. |
|
|
VTR unit operation | The cleaning roller is actuated to clean the |
| heads (max. 3 seconds). Recording continues |
| but it may not be performed properly. |
| The warning display remains flashing up to the |
| REC/PAUSE mode. It goes out when the unit’s |
| mode is transferred from REC/PAUSE. |
|
|
Remedial action | Clean the heads. If recording still cannot be |
| performed properly even after they have been |
| cleaned, turn off the unit’s power, and consult |
| your nearest service centre. |
|
|
∫ SERVO
WARNING lamp | Flashes four times per second (during recording |
| and playback). |
|
|
Tally lamp | Flashes four times per second (during recording |
| and playback). |
|
|
Viewfinder | The SERVO display flashes (during recording |
| and playback). |
|
|
Description of warning | The servo is out of sync. |
|
|
VTR unit operation | Operation continues but it may not be performed |
| properly. |
|
|
Remedial action | Turn off the unit’s power, and consult your |
| dealer. |
|
|
∫ HUMID
WARNING lamp | ≥ Lights when condensation has been detected. |
| ≥ Flashes once a second from 10 minutes after |
| the condensation detection has been released |
| for a duration of 80 minutes. |
|
|
Tally lamp | ≥ Flashes four times per second starting at the |
| time when the condensation was detected |
| until 10 minutes have elapsed after the |
| condensation detection was released. |
| ≥ The lamp turns off 10 minutes after the |
| condensation detection status is released. |
|
|
Viewfinder | The HUMID display flashes starting at the time |
| when the condensation was detected until 90 |
| minutes have elapsed after the condensation |
| detection was released. |
|
|
Description of warning | Condensation has formed. |
|
|
VTR unit operation | The recording operation continues but it will stop |
| if the tape sticks. For 80 minutes after the |
| condensation detection was released, the |
| operation which causes the drum to rotate is not |
| acknowledged. |
|
|
Remedial action | Stop the tape travel, and turn off the unit’s |
| power. If the HUMID display fails to go out even |
| after the power has been turned back on, wait |
| until it goes out. |
|
|
∫TAPE NEAR END
WARNING lamp | Flashes once per second (during recording). |
|
|
Tally lamp | Flashes once per second (during recording). |
|
|
Viewfinder | ≥ The remaining tape display flashes (in the EE |
| mode) |
| ≥ = flashes for 3 seconds one minute before |
| the |
|
|
Description of warning | The tape is approaching its end (2 minutes |
| remain). |
|
|
VTR unit operation | Operation continues. |
|
|
Remedial action | Replace the cassette tape as necessary. |
|
|
38 (E)