Adjustment

When adjusting the phase of SD signals

Observe the waveforms of the external synchronizing input signal (black burst signal) and video output signal on a two-channel oscilloscope.

Then match the horizontal phase of both signals by adjusting them with the horizontal phase control of the camera menu.

Select [H Phase] on the G/L Set sub menu.

Adjust the horizontal phase with the UP/ABB and DOWN/BAR switch.

The level of [H Phase] adjustment can be selected with [H Phase, SC Fine Step].

Genlock input signal (black burst)

Video signal

Adjust the horizontal phase

Adjustment by camera menu

Press the DOWN/BAR switch for over 2 seconds to display the color bar.

Press the MENU switch for 3 seconds or more to display the main menu.

Press the UP/ABB switch or the DOWN/BAR switch to move the cursor to [G/L Set], then press the ENTER/AWB switch to display the G/L Set sub menu.

- 58 -

MENU switch

ENTER/AWB switch

UP/ABB switch DOWN/BAR switch

G/L Set

 

H Phase

0

SC

Coarse

90deg

SC

Fine

0

H Phase,SC Fine Step 1

Return

Page 58
Image 58
Panasonic AW-HE870N operating instructions When adjusting the phase of SD signals, Adjustment by camera menu