Troubleshooting

Symptom

Cause and remedial action

Reference

pages

 

 

Multiple color bands

 

P.16,

(color bars) are

Switch to the camera picture.

P.39 to 48

displayed

 

 

 

 

 

 

The controller’s

Restart the unit, and check that “Fan Error” is displayed.

 

H/F and OPTION

 

The cooling fan inside the unit has reached the end of its service life or it has

P.9,

indicators flash

failed.

P.39 to 48

The OPERATE LED

If the camera would be kept using with displaying “Fan Error”, it may cause

 

on the CB400 flashes

malfunctioning. Ask your dealer to replace it.

 

 

 

 

 

The cooling fan inside the unit has reached the end of its service life or it

 

“Fan Error” is

has failed.

 

If the camera would be kept using with displaying “Fan Error”, it may

 

displayed when

cause malfunctioning. Ask your dealer to replace it.

P.9

operation is started

“Fan Error” is displayed in all video outputs regardless of the AWB/ABB

 

 

operation status display setting or character output selection. To clear the

 

 

“Fan Error” display, display the menu screen and close the screen.

 

 

 

 

The AWC or ABC

The AWB or ABB adjustment was not completed successfully.

 

button lights when

 

Review the shooting conditions, and try again.

P.53, P.54

the controller’s AWC

The reason why the adjustment was not completed successfully can be

P.55, P.68

or ABC button is

checked when the AWB/ABB operation status display (Status) is set to ON.

 

pressed

 

 

 

- 97 -

Page 97
Image 97