CS-TE9DKE CU-TE9DKE / CS-TE12DKE CU-TE12DKE

9.4.Airflow Direction Control

Vertical louver is controlled with Vertical Airflow Direction button on remote controller and by operation conditions, as shown in the table below.

9.4.1.Vertical Airflow Louver Angle

Cooling and Dry Operations

Airflow Direction Auto

Airflow Direction Setting

Manual Operation

Vertical Auto Operation

Powerful-ON

 

 

•• The louver is fixed at five-level setting

•• It swings when airflow direction is set with

 

position when the airflow direction is set with

 

remote controller.

remote controller.

 

 

 

•• It does not swing while indoor fan is

 

 

stopped. (It is fixed at the upper limit.).

 

 

 

 

 

 

Heating Operation

 

Airflow Direction Auto

Airflow Direction Setting

Fixed by Heat Exchanger Temperature

Powerful Operation

Remote Control

•• When Heat Exchanger Temperature is less

•• When Heat Exchanger Temperature is less

 

than 33°C

than 33°C

 

•• When Heat Exchanger Temperature is

•• When Heat Exchanger Temperature is

•• The louver is fixed at five-level setting

between 33°C (, incl.) and 127°C

between 33°C (, incl.) and 127°C

position when the airflow direction is set with

 

 

remote controller.

 

 

 

Airflow Direction Auto

Airflow Direction Setting

Odour Removal Control

 

 

 

 

 

••The vertical louver is fully opened and move to the setting position when the unit is turned on with the remote controller.

••The vertical louver remains open position when the unit is turned off during operation.

••The horizontal louver is manually operated.

23