9.4.Airflow Direction Control
Vertical louver is controlled with Vertical Airflow Direction button on remote controller and by operation conditions, as shown in the table below.
9.4.1.Vertical Airflow Louver Angle
Cooling and Dry Operations
Airflow Direction Auto | Airflow Direction Setting | |
Manual Operation | Vertical Auto Operation | |
|
| •• The louver is fixed at |
•• It swings when airflow direction is set with |
| position when the airflow direction is set with |
| remote controller. | |
remote controller. |
| |
|
| |
•• It does not swing while indoor fan is |
|
|
stopped. (It is fixed at the upper limit.). |
|
|
|
|
|
| Heating Operation |
|
Airflow Direction Auto | Airflow Direction Setting | |
Fixed by Heat Exchanger Temperature | Powerful Operation | Remote Control |
•• When Heat Exchanger Temperature is less | •• When Heat Exchanger Temperature is less |
|
than 33°C | than 33°C |
|
•• When Heat Exchanger Temperature is | •• When Heat Exchanger Temperature is | •• The louver is fixed at |
between 33°C (, incl.) and 127°C | between 33°C (, incl.) and 127°C | position when the airflow direction is set with |
|
| remote controller. |
|
|
|
Airflow Direction Auto | Airflow Direction Setting | |
Odour Removal Control |
|
|
|
|
|
••The vertical louver is fully opened and move to the setting position when the unit is turned on with the remote controller.
••The vertical louver remains open position when the unit is turned off during operation.
••The horizontal louver is manually operated.