CS-TE9DKE CU-TE9DKE / CS-TE12DKE CU-TE12DKE

9.7.2.Dry Operation

••Airflow direction, Fan speed and Setting temperature are optimized.

••“Intake Air temperature - Remote controller setting temperature” is detected every 20 seconds by indication from indoor unit and controlled to each area.

Quick Dry Unit forcibly turns to Quick Dry operation for 5 minutes after POWERFUL ON even through it is in the stable area. If unit gets out of the area, it turns to Chilly Dry operation.

Chilly Dry Discharge Air temperature is kept low by changing fan speed according to room temperature and chilly feeling is produced.

9.7.3.Heating Operation

••Airflow direction, Fan speed and Setting temperature are optimized.

••“Intake Air temperature - Remote controller setting temperature” is detected every 20 seconds by indication from indoor unit and controlled to each area.

Quick Heating Unit forcibly turns to Quick Heating operation for 5 minutes after POWERFUL ON even through it is in the stable area. If unit gets out of the area, it turns to Warm Heating operation.

Warm Heating Discharge Air temperature is kept high by changing fan speed according to room temperature and warm feeling is produced.

9.8.Automatic Operation

••Operation mode (Cooling, Dry and Heating) is automatically selected.

••Operation mode is selected at the beginning of unit operation and every 30 minutes. Temperature, Fan speed and Airflow directions are set with remote controller.

9.8.1.Operation Mode Selection

Operation mode is selected according to outdoor temperature, intake air temperature and setting temperature.

1."Heating" is selected when intake air temperature is below 16 °C.

2."Cooling" is selected when intake air temperature is 25 °C or more. (But, when intake air temperature is 16 °C or more.)

3.Selectable range of "Heating" and "Cooling" for setting temperature on the remote controller is increased when outside air temperature is below 25 °C.

9.8.2.Setting Temperature Shift in Automatic Operation

••When Cooling mode is selected, setting temperature is shifted to +1 °C.

••When Heating mode is selected, setting temperature is shifted to -1 °C.

30