Image 10

Indoor Unit

CS-KE36NKU

 

 

 

 

 

 

 

Outdoor Unit

CU-KE36NKU

 

 

 

 

 

 

< 208V >

 

 

 

 

 

 

 

 

 

 

 

Voltage Rating

 

 

 

 

 

 

208V Single-Phase 60Hz

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Cooling

 

Heating

Performance

 

 

 

 

 

 

 

 

 

 

Total Capacity

 

 

 

 

BTU/h

34,000

( 10,900 to 34,000 )

36,000

( 14,000 to 36,000 )

 

 

 

 

 

 

kW

10.0

( 3.2 to 10.0 )

10.5

( 4.1 to 10.5 )

Sensible Capacity

 

 

 

 

BTU/h

 

20,700

 

-

Latent Capacity

 

 

 

 

BTU/h

 

13,300

 

-

Air Circulation (Hi/Me/Lo)

ft3/min (m3/h)

630(1,070)/530(901)/412(700)

671(1,140)/559(950)/441(749)

 

Moisture Removal (High)

 

 

Pints/h

 

10.64

 

-

 

Available Voltage Range

 

 

V

 

187 to 253

 

 

Running Amperes

 

 

 

 

A

21.9

( 5.0 to 21.9 )

19.9

( 4.5 to 19.9 )

Rating

Power Input

 

 

 

 

 

W

4,000

( 1,000 to 4,000 )

3,650

( 900 to 3,650 )

 

 

 

 

 

 

 

Power Factor

 

 

 

 

%

 

88

 

88

Electrical

EER

 

 

 

 

 

BTU/h/W

 

8.50

 

-

HSPF

 

 

 

 

 

BTU/Wh

 

-

 

9.0

 

COP

 

 

 

 

 

W/W

 

-

 

2.89

 

SEER

 

 

 

 

 

BTU/Wh

 

16.0

 

-

 

 

 

 

 

 

 

 

 

 

 

Compressor Locked Rotor Amperes

 

 

A

 

31.0

 

 

Fuse or Circuit Breaker Capacity

 

 

A

 

45

 

 

Controls / Temperature Control

 

 

 

 

Microprocessor / I.C. Thermister

 

Control Unit

 

 

 

 

 

 

 

Wireless Remote Control Unit

 

Timer

 

 

 

 

 

 

 

24-Hour ON or OFF Timer, 1-Hour OFF Timer

 

Fan Speeds

 

Indoor / Outdoor

 

Auto and 3 steps / Auto (Hi, Me, Lo)

 

Airflow Direction (Indoor)

 

 

Horizontal

 

Manual

 

 

 

 

 

 

 

 

Vertical

 

Auto

 

Features

Air Filter

 

 

 

 

 

 

 

Washable, Anti-Mold

Compressor

 

 

 

 

 

 

DC Twin Rotary (Inverter)

 

 

 

 

 

 

 

 

Refrigerant / Amount charged at shipment

 

 

Ibs (g)

 

R410A / 6.5 (2,950)

 

Refrigerant Control

 

 

 

 

 

 

Electric Expansion Valve

 

 

 

 

 

 

 

 

 

Operation Sound

 

Indoor : Hi/Me/Lo/Qt*

dB-A

49 / 44 / 39 / 32

49 / 44 / 39 / 32

 

(*Qt = Quiet mode)

 

Outdoor : Hi

 

 

dB-A

 

55

 

56

 

Refrigerant Tubing Connections

 

 

 

 

Flare Type

 

 

Max. allowable tubing length at shipment

 

 

ft (m)

 

164 (50)

 

 

Refrigerant

 

 

Narrow tube

 

 

inch (mm)

 

3/8 (9.52)

 

 

Tube Diameter

 

Wide tube

 

 

inch (mm)

 

5/8 (15.88)

 

 

Refrigerant Tube Kit

 

 

 

 

 

 

Optional

 

Weight

 

 

 

 

 

 

 

 

Indoor Unit

 

Outdoor Unit

 

 

 

 

 

 

 

 

 

 

 

Unit Dimensions

 

 

 

 

inch

11-13/16 σ 41-15/16 σ 9-1/16

35-13/16 σ 37-1/32 σ 13-3/8

&

Height σ Width σ Depth

 

 

(mm)

(300 σ 1,065 σ 230)

(910 σ 940 σ 340)

Package Dimensions

 

 

inch

12-7/32 σ 44-7/8 σ 14-31/32

42-3/8 σ 40 σ 16-3/8

Dimensions

 

 

Shipping Volume

σ Depth

 

 

cu.ft (m3)

 

4.59 (0.13)

 

15.88 (0.45)

 

Height

σ Width

 

 

(mm)

(310 σ 1,140 σ 380)

(1,076 σ 1,016 σ 416)

 

Weight

 

 

Net

 

 

Ibs (kg)

 

32.0 (14.5)

 

185.2 (84.0)

 

 

 

 

Shipping

 

 

Ibs (kg)

 

39.7 (18.0)

 

207.2 (94.0)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DATA SUBJECT TO CHANGE WITHOUT NOTICE.

Remarks: Rating conditions are:

 

 

 

 

Cooling: Indoor air temperature

80 °F DB / 67 °F WB

Heating: Indoor air temperature

70

°F DB

Outdoor air temperature

95 °F DB / 75 °F WB

Outdoor air temperature

47

°F DB / 43 °F WB