Panasonic CU-KE30NKU Outdoor Unit, P.C.Board, Compressor, Fan Motor, Heat Exchanger Coil

Models: CS-KE30NKU CS-KE36NKU CU-KE30NKU CU-KE36NKU

1 112
Download 112 pages 47.47 Kb
Page 13
Image 13

2-2-2. Outdoor Unit

Outdoor Unit CU-KE30NKU

P.C.Board

 

 

Control P.C.B

 

Noise Filer P.C.B

 

H.I.C.Board

 

 

 

 

 

 

 

 

 

 

 

Part No.

 

 

CR-CH3082-F

 

POW-CH3082-B2

 

HIC-CH3072R-C1

 

Controls

 

 

Microprocessor

 

-

 

-

 

Circuit Fuse

 

 

400V 3.15A

 

250V 25A

 

-

 

 

 

 

 

 

 

 

 

Compressor

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Type

 

 

 

DC Twin Rotary (Hermetic)

 

Compressor Model / Nominal Output

 

 

 

C-9RVN273H0H / 2,250W

 

Compressor Oil ... Amount

Pints (cc)

 

FV68S ... 2.98 (1,400)

 

 

Coil Resistance (Ambient Temp. 77 °F (25 °C)) Ohm

 

 

T - R : 0.169

 

 

 

 

 

 

 

 

T - S : 0.169

 

 

 

 

 

 

 

 

R - S : 0.169

 

 

Safety Device

 

 

 

 

 

 

 

 

 

CT (Peak current cut-off control)

 

 

Yes

 

 

 

Compressor Discharge Temp. Control

 

 

Yes

 

 

 

Operation cut-off control in abnormal ambient Temp.

 

 

Yes

 

 

 

Overload Relay

 

Model

 

 

CS-7L110

 

 

 

 

Operation Temp.

Open : 230 °F (110 °C), Close : 203 °F (95 °C)

 

Run Capacitor

 

Micro F

 

-

 

 

 

 

 

 

VAC

 

-

 

 

 

Crankcase Heater

 

 

 

 

230V 30W

 

 

 

 

 

 

 

 

 

 

 

Fan

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Type

 

 

 

 

Propeller

 

 

Q'ty ... Dia.

inch (mm)

 

 

1 ... D19-9/32 (D490)

 

 

 

 

 

 

 

 

 

 

Fan Motor

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Type

 

 

 

 

DC Motor

 

 

Model ... Q'ty

 

 

 

SIC-71FW-D8120-4A ... 1

 

No. of Poles

 

 

 

8

 

 

 

Rough Measure RPM (Cool / Heat)

 

 

 

750 / 750

 

 

 

Nominal Output

 

W

 

142

 

 

 

Coil Resistance

 

Ohm

 

 

 

 

 

 

(Ambient Temp. 68 °F (20 °C))

 

 

 

-

 

 

 

 

 

 

 

 

 

 

 

 

 

Safety Device

 

 

 

 

 

 

 

 

 

Type

 

 

 

 

Internal Controller

 

 

 

Over- Current Protection

 

 

 

 

Yes

 

 

 

Over- Heat Protection

 

 

 

 

Yes

 

 

Run Capacitor

 

Micro F

 

-

 

 

 

 

 

 

VAC

 

-

 

 

 

 

 

 

 

 

 

 

 

 

Heat Exchanger Coil

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Coil

 

 

Aluminum Plate Fin / Copper Tube

 

Rows

 

 

 

2

 

 

 

Fins per inch

 

 

 

21.2

 

 

 

Face Area

 

ft2 (m2)

 

8.05 (0.748)

 

 

 

 

 

 

External Finish

 

 

Acrylic baked-on enamel finish

 

 

 

 

 

 

 

 

 

 

DATA SUBJECT TO CHANGE WITHOUT NOTICE.