SAFETY PRECAUTIONS

Before doing repair work, please read the "SAFETY PRECAUTIONS" carefully and fully understand them.

The precautionary items here are divided into "Warning" and "Caution" items.

Items in particular which may cause death or serious injury to the service personnel if the work is not performed correctly,

are included in the "Warning" table.

However, even precautionary items identified as " Caution" also have the potential for serious consequences if not performed correctly.

Important safety precautions are described for all items in both categories. Be sure to carefully follow all of them.

Symbol Indication

: This symbol indicates items to which we need to pay attention. In this triangle, a definite precautionary item is described.

: This symbol indicates the item to be prohibited.

In or close to this circle, a prohibited item is described.

: This symbol indicates the items requiring special attention or instruction. In or close to this circle, a prohibited item is described.

After doing repair work, perform a test run to confirm that there are no abnormalities. At the same time, explain the precautions in use to the user.

Warning

Before performing an overhaul, disconnect the power plug or power cable from the unit.

Performing the work with the power supplied to the unit, may cause an electric shock.

When repair work or circuit inspection that requires power supply for the air conditioner, is to be performed,

 

do not touch the charging section.

 

Doing so may cause an electric shock.

Prohibit

For the step-up capacitor attached to the electric section, perform the repair work after sufficiently discharging it. Insufficient capacitor discharge may cause an electric shock.

Do not perform repair work on the electric sections with wet hands.

Doing so may cause an electric shock.

Prohibit

Do not start or stop the air conditioner by means of connecting or disconnecting the power plug.

Doing so may cause an electric shock or fire.

Prohibit

When conducting repair work only use components included in the parts list for the corresponding unit and perform the work with the appropriate tools.

Incorrect or poor repair work may cause an electric shock or fire.

Never modify the unit.

Doing so may cause an electric shock or fire.

Prohibit

Perform all electric work according to local applicable regulations related to electrical equipment or interior wiring regulation and make sure to use the exclusive circuit.

Insufficient capacity to the electric circuit or defective arrangement results may cause an electric shock or fire.

Make sure to replace any power cable or lead wire showing any signs of scratch or deterioration.

Failure to do so may cause an electric shock, overheating or fire.

Make sure that there is no dust on or slack in the power plug and insert fully into the socket.

Dust or incomplete connections may cause an electric shock or fire.

Do not damage or process the power cord, as it may cause an electric shock or fire.

Prohibit

For the wiring between the indoor unit and outdoor unit, securely fix the specified cable onto the terminal plate. Poorly fixed wiring may cause a heat or fire.

After connecting the wiring between the indoor unit and outdoor unit, attach the terminal cover securely. Incomplete attachment of the terminal cover may cause overheating or fire.

2

Page 2
Image 2
Panasonic CS-KE36NKU, CU-KE36NKU, CU-KE30NKU, CS-KE30NKU service manual Safety Precautions

CS-KE30NKU, CS-KE36NKU, CU-KE30NKU, CU-KE36NKU specifications

The Panasonic CU-KE36NKU, CS-KE36NKU, CU-KE30NKU, and CS-KE30NKU air conditioning units represent the brand's commitment to delivering high-performance cooling solutions backed by innovative technologies. These units cater to both residential and commercial applications, ensuring users experience maximum comfort throughout the year.

One of the standout features of these models is their energy efficiency. Both units are equipped with advanced inverter technology, which allows for variable speed operation. This means they can adjust their power output according to the room's cooling needs, reducing energy consumption and minimizing electric bills while maintaining a consistent temperature. The models boast impressive SEER (Seasonal Energy Efficiency Ratio) ratings, making them environmentally friendly options.

Panasonic's nanoe-G technology is another remarkable feature incorporated into these models. This technology helps to purify the air by generating hydroxyl radicals, which eliminate airborne particles, odors, and harmful bacteria. This results in a healthier indoor environment, conducive to both comfort and well-being. The air purification aspect not only enhances the air quality but also extends the lifespan of the HVAC system by reducing the buildup of dust and contaminants.

In terms of user convenience, both the CU-KE and CS-KE series are equipped with programmable timers, allowing users to set their desired operation schedules. They also come with a remote control for ease of use, enabling adjustments from a distance. The installation process is straightforward, and the sleek design blends seamlessly with various interior aesthetics, making them a suitable choice for any room.

Durability is a key characteristic of Panasonic air conditioning units, and the CU-KE36NKU, CS-KE36NKU, CU-KE30NKU, and CS-KE30NKU are designed to withstand varying environmental conditions. Their robust construction ensures reliability and performance over the years. Additionally, both models come with a quiet operation feature that minimizes noise levels, allowing for comfortable use without disturbing daily activities.

In summary, the Panasonic CU-KE36NKU, CS-KE36NKU, CU-KE30NKU, and CS-KE30NKU are exceptional air conditioning units that combine energy efficiency, innovative purification technology, user-friendly features, and robust durability. These models are an ideal investment for anyone seeking a reliable and high-performance cooling solution.