1 112
Download 112 pages 47.47 Kb
Page 26
Image 26
Manual background

Indoor Unit

: CS-KE36NKU

 

 

 

 

 

 

 

 

 

 

 

Outdoor Unit

: CU-KE36NKU

 

 

 

 

 

 

 

 

 

 

 

Power Supply : 230V Single Phase 60Hz

 

 

 

 

 

 

 

 

 

 

< Cooling Capacity (Low Ambient) >

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RATING CAPACITY:

34,000 BTU/h

 

AIR FLOW RATE:

 

630 CFM

 

 

INDOOR

 

 

 

 

OUTDOOR

 

 

 

 

 

ENT. TEMP. oF (oC)

 

 

 

 

AMBIENT TEMP.oF (oC)

 

 

 

 

WB

DB

 

 

0

5

15

 

25

 

35

45

55

 

 

 

 

 

 

(-17.8)

(-15.0)

(-9.4)

 

(-3.9)

 

(1.7)

(7.2)

(12.8)

 

 

 

 

TC

 

30,900

30,870

30,800

 

30,710

 

30,590

30,400

30,210

 

 

 

72 (22.2)

SHC

 

21,510

21,510

21,510

 

23,230

 

21,390

21,270

21,150

 

 

59

76 (24.4)

SHC

 

23,960

23,840

23,840

 

25,550

 

23,710

23,590

23,470

 

 

(15.0)

80 (26.7)

SHC

 

26,400

26,400

26,280

 

27,870

 

26,160

26,040

25,920

 

 

 

84 (28.9)

SHC

 

28,730

28,730

28,610

 

30,200

 

28,480

28,480

28,360

 

 

 

88 (31.1)

SHC

 

30,900

30,870

30,800

 

30,710

 

30,590

30,400

30,210

 

 

 

 

TC

 

31,010

31,010

30,990

 

30,950

 

30,890

30,750

30,620

 

 

 

72 (22.2)

SHC

 

17,970

17,970

17,970

 

23,230

 

17,970

17,840

17,840

 

 

63

76 (24.4)

SHC

 

20,410

20,410

20,290

 

25,550

 

20,290

20,170

20,170

 

 

(17.2)

80 (26.7)

SHC

 

22,860

22,860

22,740

 

27,870

 

22,740

22,610

22,610

 

 

 

84 (28.9)

SHC

 

25,180

25,180

25,180

 

30,200

 

25,060

25,060

24,940

 

 

 

88 (31.1)

SHC

 

27,510

27,510

27,510

 

30,950

 

27,380

27,380

27,260

 

 

 

 

TC

 

30,910

30,940

30,980

 

31,000

 

31,010

30,930

30,880

 

 

 

72 (22.2)

SHC

 

14,420

14,420

14,420

 

23,230

 

14,420

14,420

14,420

 

 

67

76 (24.4)

SHC

 

16,740

16,740

16,740

 

25,550

 

16,740

16,740

16,740

 

 

(19.4)

80 (26.7)

SHC

 

19,190

19,190

19,190

 

27,870

 

19,190

19,190

19,190

 

 

 

84 (28.9)

SHC

 

21,510

21,510

21,640

 

30,200

 

21,640

21,510

21,510

 

 

 

88 (31.1)

SHC

 

23,840

23,960

23,960

 

31,000

 

23,960

23,960

23,840

 

 

 

 

TC

 

30,570

30,620

30,730

 

30,820

 

30,910

30,900

30,930

 

 

 

72 (22.2)

SHC

 

10,630

10,630

10,750

 

23,230

 

10,750

10,750

10,750

 

 

71

76 (24.4)

SHC

 

12,950

12,950

13,070

 

25,550

 

13,070

13,070

13,070

 

 

(21.7)

80 (26.7)

SHC

 

15,400

15,400

15,520

 

27,870

 

15,520

15,520

15,520

 

 

 

84 (28.9)

SHC

 

17,720

17,840

17,840

 

30,200

 

17,970

17,970

17,970

 

 

 

88 (31.1)

SHC

 

20,170

20,170

20,170

 

30,820

 

20,290

20,290

20,290

 

 

 

 

TC

 

30,010

30,090

30,260

 

30,430

 

30,590

30,650

30,770

 

 

75

76 (24.4)

SHC

 

9,410

9,410

9,530

 

25,550

 

9,650

9,650

9,650

 

 

(23.9)

80 (26.7)

SHC

 

11,850

11,850

11,970

 

27,870

 

12,100

12,100

12,100

 

 

 

84 (28.9)

SHC

 

14,180

14,180

14,300

 

30,200

 

14,420

14,420

14,420

 

 

 

88 (31.1)

SHC

 

16,500

16,620

16,620

 

30,430

 

16,740

16,740

16,870

 

 

 

 

TC : Total Cooling Capacity (BTU/h)

SHC : Sensible Heat Capacity (BTU/h)

NOTE

1.Above data does not take Freeze Prevention Protection during cooling operation into account. For this reason, the value may vary from the actual cooling characteristics.

2.Above data represents the value when the operation frequency of a compressor is fixed.

26