Instructions for the data fields

a.

b.

External Sensor Input of External I/O activates the alarm trigger. Refer to page 91.

Active Time of Trigger

The active trigger time can be set in the primary time and the secondary time. The secondary time is the supplement of the primary time.

Always: always activates the alarm trigger.

Operational between: Sets the start and stop time of the primary time. The day of the week can be set by checking. Start and stop time is set only in 24 h time mode.

Alarm enable condition:

Select the [Rising] (GND to Open High) or [Falling] (Open High to GND) of External Sensor Input of the External I/O.

c.Secondary time is active trigger time except the primary time. Alarm enable condition:

Select the [Rising] (GND to Open High) or [Falling] (Open High to GND) of External Sensor Input of the External I/O.

d.

e.

Sets the image resolution and image quality.

Image resolution: 640 x 480/320 x 240/160 x 120

Image quality: Favor Clarity/Standard/Favor Motion

The Pre or Post trigger or both can be set on the Buffered Image. Check the box.

f.Image Frequency: Sets the interval to send the image. Maximum number of images per each trigger:

Selects the number of buffering frames from numbers 1 to 400.