Operating Instructions

Setting explanation

a.

b.

c.

d.

e.

f.

The active time of trigger is set between 9:00 AM to 6:00 PM from Monday to Friday.

When the alarm occurs in the setting time, the images are transferred to FTP server, and the notification is sent to the specified user via e- mail.

The alarm trigger is on when the sensor signal is changed to the [Rising] (GND to Open High) of External Sensor Input of External I/O.

The secondary time is set inactive.

The transferring image size is 160 x 120, and the image quality is standard.

Enables the Pre-alarm and Post-alarm Image Buffering:

Network Camera will transfer Pre-alarm 10 images by one image per minute and Post-alarm 20 images by one image per second when detecting the alarm trigger.

Setting of FTP server:

IP Address — 192.168.0.20 Port No. — 21

Login ID — Panasonic Password — ********

Login timing: Every Time

Upload File name — NetworkCamera

File name and time stamp is named to the file. (Example: NetworkCamera20030101093000000.jpg)

Underlined numbers are "9 h 30 min 00 s 000 ms on January 1, 2003". Data transfer method — Passive Mode

SMTP server address — xxx.xxx.com POP3 server address — xxx.xxx.com Login ID — Panasonic

Password — ********

Mail is sent to "NetworkCamera@xxx.xxx.com" from "Panasonic@xxx.xxx.com".

Subject is [Mail Transfer]. Text is [Alarm was generated].