4.1 Troubleshooting
4.1.3Operation
| PROBLEM |
| PROBABLE CAUSE | SOLUTION |
|
|
|
|
|
• | When using the | • | The HANDSET/HEADSET | • When the headset is not used, set the |
| speakerphone on an APT, |
| selector is set to the | HANDSET/HEADSET selector to the |
| nothing is audible. |
| "HEADSET" position. | "HANDSET" position. |
• | When using the | • The "HEADSET" mode is | • When the headset is not used, select | |
| speakerphone/monitor |
| selected by Personal | the "HANDSET" mode by Personal |
| mode with a DPT, nothing is |
| Programming, "Handset/ | Programming. |
| audible. |
| Headset Selection". |
|
|
|
| ||
• The PT does not ring. | • The ringer volume is off. | • Turn on the ringer volume. | ||
|
|
| ||
• During a power failure, | • A DPT or APT is connected | • Disconnect the DPT or APT and | ||
| extensions connected to |
| to the extension port. | connect an SLT. |
| ports 1 and 2 of super hybrid | • The dialing mode (tone or | • Set the Tone/Pulse switch to the other | |
| ports do not operate. |
| pulse) is incorrect. | position. |
|
|
| ||
|
|
|
| |
• Originating an outside call, | • | The corresponding CO | • Program the CO button. Refer to "1.6.3 | |
| call transfer, or conference |
| button does not exist on the | Flexible Buttons" in the Feature |
| cannot be performed. |
| PT. | Manual. |
|
|
|
| |
• Cannot register the PS. | • | Wrong Personal | • Enter the PIN set to the Hybrid | |
|
|
| Identification Number (PIN) | into the PS. |
|
|
| is registered to the PS. |
|
|
| • CS is not connected | • Make sure that the cable is connected | |
|
|
| properly. | properly with correct pin assignments. |
|
|
|
| Also, make sure that the cable does not |
|
|
|
| make short circuits. |
|
|
|
| • Switch all DIP switches off. |
|
|
| ||
• PS becomes out of range. | • CS is not working. | • Make sure that the cable is connected | ||
• Cannot make calls using the |
|
| properly with correct pin assignments. | |
|
| Also, make sure that the cable does not | ||
| PS. |
|
| |
|
|
| make short circuits. | |
|
|
|
| |
|
|
|
| • Switch all DIP switches off. |
|
| • Location of CS is not good. | • Locate the CS properly (refer to "2.7.5 | |
|
|
|
| Site Survey" ). |
|
| • Access system of the PS is | • Change the access system setting of | |
|
|
| not properly set. | the PS to the appropriate system or |
|
|
|
| automatic. |
|
|
|
|
|