2.7 Connection of 2.4 GHz Portable Stations

2.7Connection of 2.4 GHz Portable Stations

2.7.1Overview

The following equipment is required to connect the wireless system:

CS: Cell Station (KX-T0141)

This unit determines the area covered by the wireless system. Up to 2 calls can be made at the same time through each CS.

PS: 2.4 GHz Portable Station (KX-TD7680/KX-TD7690)

The KX-TDA50 can support up to 28 PSs. For more details about the PS, refer to the PS Operating Instructions.

CAUTION

The CS should be kept free of dust, moisture, high temperature (more than 40 °C [104 °F]), low temperature (less than 0 °C [32 °F]), and vibration, and should not be exposed to direct sunlight.

The CS should not be placed outdoors (use indoors).

The CS should not be placed near high-voltage equipment.

The CS should not be placed on a metal object.

Systems using 2.4 GHz ISM (Industrial, Scientific and Medical) band may interfere with the KX- TDA wireless system. Examples of such systems are cordless telephones, wireless LAN, Home RF, microwave ovens and other ISM devices. These systems may cause minor noise.

Keeping some distance between the equipment listed below may prevent interference. (The distance may vary depending on the environment.)

Equipment

Distance

 

 

CS and office equipment such as a computer, telex, fax

More than 2 m (6 ft 7 in)

machine, etc.

 

 

 

CS and PS

More than 1 m (3 ft 3 in)

 

 

Each PS

More than 0.5 m (1 ft 8 in)

 

 

Hybrid IP-PBX and CS

More than 2 m (6 ft 7 in)

 

 

CS and CS

More than 15 m (49 ft)

 

 

Please take into consideration the distance between the CSs when site planning. Please consult a certified dealer for details.

However, the required distance between CSs may vary depending on the environment of the installation site and conditions in which the wireless system is used. Conduct the site survey to determine the appropriate distance.

94

Installation Manual

Page 94
Image 94
Panasonic KX-TDA50 Connection of 2.4 GHz Portable Stations, Overview, CS Cell Station KX-T0141, Equipment Distance