2.2 Installation of the Hybrid IP-PBX
2.2.11 Surge Protector Installation
Overview
A massive electrical surge can be caused if lightning strikes a telephone cable 10 m (33 ft) above ground, or if a telephone line comes into contact with a power line. A surge protector is a device that is connected to a CO line to prevent potentially dangerous electrical surges from entering the building via the CO line and damaging the Hybrid
To protect the system from electrical surges, we strongly recommend connecting the system to a surge protector that meets the following specifications:
•Surge arrestor type:
•DC
•Maximum peak current: at least 10 kA
Additionally, proper grounding is very important for the protection of the system (refer to "2.2.5 Frame Ground Connection").
Many countries/areas have regulations requiring surge protection. Be sure to comply with all applicable laws, regulations, and guidelines.
Installation
CO Line
Surge
Protector
CO Line
Terminal
Board
Extn. Extn. Extn.
CO Line
Extn.
Hybrid
SLT
PT
CS
Frame Ground
Ground | Extn.: Extension line |
|
Installation Manual
59