2.6 Connection of Extensions
2.6.3Digital EXtra Device Port (Digital XDP) Connection
A DPT can be connected to another DPT on the Digital XDP connection. In addition, if the DPT is connected to a Super Hybrid Port, it can also have an SLT connected in Parallel mode or XDP mode.
Notes
•Both DPTs must be
•Parallel mode or XDP mode can be selected through system programming.
•If XDP mode is enabled through system programming, parallel connection is not possible. Refer to "1.13.2 Paralleled Telephone" and "1.5.7 Extension Port Configuration" in the Feature Manual for further information.
With KX-T7600 Series DPT
Using a Modular T-Adaptor
To DLC4/DLC8 card
To a Super Hybrid Port
(for connection of SLT)
Modular
Connect pins "T" and "R".
SLT
Master DPT | Slave DPT |
Back View of DPTs
TO TEL
Cable | Maximum Distance |
26 AWG: | 30 m (98 ft) |
24 AWG: | 50 m (164 ft) |
22 AWG: | 60 m (196 ft) |
CAT 5: | 50 m (164 ft) |
TO MAIN UNIT |
|
|
/ PABX | Master DPT | Slave DPT |
| ||
| To DLC4/DLC8 card |
|
TO MAIN UNIT / PABX
To a Super Hybrid Port (for connection of SLT)
Installation Manual
91