2.8 Connection of Doorphones, Door Openers, External Sensors, and External Relays

2.8Connection of Doorphones, Door Openers, External Sensors, and External Relays

2.8.1Connection of Doorphones, Door Openers, External Sensors, and External Relays

A maximum of 4 doorphones (KX-T30865), 4 door openers or external relays, and 4 external sensors can be connected to the Hybrid IP-PBX.

Note

Doorphones, door openers, external sensors, and external relays are user-supplied.

Maximum Cabling Distance

Cable

Maximum Distance

26 AWG:

70 m (230 ft)

24 AWG:

113 m (371 ft)

22 AWG:

180 m (590 ft)

CAT 5:

113 m (371 ft)

 

 

Installing the Doorphone (KX-T30865)

1.Loosen the screw to separate the doorphone into 2 halves.

Doorphone

Door Opener

External Sensor/

External Relay Device

anasonic P

Screw

116 Installation Manual