Panasonic KX-TDA50 installation manual Characteristics

Models: KX-TDA50

1 158
Download 158 pages 20.93 Kb
Page 27
Image 27

1.4 Specifications

1.4.2Characteristics

Terminal Equipment Loop Limit

• PT: KX-T7600 series DPT: 90 ; all other DPTs/APTs: 40

 

• SLT: 600 including set

 

• Doorphone: 20

 

PT-interface CS: 65

 

 

Minimum Leakage Resistance

15 000 minimum

 

 

Maximum Number of Extension

1 for PT or SLT

Instruments per Line

2 by Parallel or eXtra Device Port connection of a PT and an SLT

 

 

3 by Digital eXtra Device Port connection of 2 DPTs and an SLT

 

 

Ring Voltage

75 Vrms at 20 Hz/25 Hz depending on the Ringing Load

 

 

Central Office Loop Limit

1600 maximum

 

 

Hookswitch Flash Timing Range

24 ms to 2032 ms

 

 

Door Opener Current Limit

24 V DC/30 V AC, 1 A maximum

 

 

External Relay Current Limit

24 V DC/30 V AC, 1 A maximum

 

 

External Sensor Current Limit

Power to the external sensor is provided from the DPH4 card and must be

 

grounded through the DPH4 card. For the connection diagram, refer to

 

"2.5.1 DPH4 Card (KX-TDA5161)".The Hybrid IP-PBX detects input from

 

the sensor when the signal is under 100 .

 

 

Paging Terminal Impedance

600

 

 

MOH Terminal Impedance

10 000

 

 

Installation Manual

27

Page 27
Image 27