FIRSTDIGIT_TIM

Value Format Integer
Description Specifies the length of time, in seconds, within which the first digits of
a dial number must be dialed. When this timer expires, the unit will play
a busy tone.
Value Range 10–600
Default Value 30

INTDIGIT_TIM

Value Format Integer
Description Specifies the length of time, in seconds, within which subsequent digits
of a dial number must be dialed. When this timer expires after the last
key was pressed, dialing will start.
Value Range 3–10
Default Value 5
Web User Interface Reference Inter-digit Timeout (Page 102)

VM_SUBSCRIBE_ENABLE

Value Format Boolean
Description Specifies whether to send the SUBSCRIBE request to a voice mail
server.
Note
Your phone system must support voice mail.
Value Range Y (Send the SUBSCRIBE request)
N (Do not send the SUBSCRIBE request)
Default Value N
Web User Interface Reference Send SUBSCRIBE to Voice Mail Server (Page 102)
4.5.2 Tone Settings

DIAL_TONE_FRQ

Value Format Comma-separated Integer
Description Specifies the dual-tone frequencies, in hertz, of dial tones using 2 whole
numbers separated by a comma.
162 Administrator Guide Document Version 2010.03.15
4.5.2 Tone Settings