Web User Interface Reference Tone Timings (Page 114)
REORDER_TONE_FRQValue Format Comma-separated Integer
Description Specifies the dual-tone frequencies, in hertz, of reorder tones using 2
whole numbers separated by a comma.
Value Range 0, 200–1000 (0: No tone)
Default Value 480,620
Web User Interface Reference Tone Frequencies (Page 114)
REORDER_TONE_TIMINGValue Format Comma-separated Integer
Description Specifies the pattern, in milliseconds, of reorder tones using 8 whole
numbers (on 1, off 1, on 2, off 2, on 3, off 3, on 4, off 4) separated by
commas.
Value Range 0–5000 (0: Infinite time)
Default Value 250,250,250,250,250,250,250,250
Web User Interface Reference Tone Timings (Page 115)
HOWLER_TONE_FRQValue Format Comma-separated Integer
Description Specifies the dual-tone frequencies, in hertz, of howler tones (i.e., alarm
tones) using 2 whole numbers separated by a comma.
Value Range 0, 200–3000 (0: No tone)
Default Value 1400,2060
Web User Interface Reference Tone Frequencies (Page 115)
HOWLER_TONE_TIMINGValue Format Comma-separated Integer
Description Specifies the pattern, in milliseconds, of howler tones (i.e., alarm tones)
using 4 whole numbers (on 1, off 1, on 2, off 2) separated by commas.
Value Range 0–5000 (0: Infinite time)
Default Value 100,100,100,100
Web User Interface Reference Tone Timings (Page 115)
Document Version 2010.03.15 Administrator Guide 165