HOWLER_START_TIME
Value Format Integer
Description Specifies the length of time, in seconds, that busy or reorder tones play
until they switch to howler tones.
Value Range 0–120 (0: Disable)
Default Value 30
Web User Interface Reference Start Time (Page 115)
BELL_CORE_PATTERN1_TIMING
Value Format Comma-separated Integer
Description Specifies the cadence, in milliseconds, of pattern ID 1, described in the
LSSGR, GR-506-CORE, "Signaling for Analog Interfaces" section 14,
using 2 whole numbers separated by a comma.
Value Range 0–5000 (0: Infinite time)
Default Value 2000,4000
BELL_CORE_PATTERN2_TIMING
Value Format Comma-separated Integer
Description Specifies the cadence, in milliseconds, of pattern ID 2, described in the
LSSGR, GR-506-CORE, "Signaling for Analog Interfaces" section 14,
using 4 whole numbers separated by commas.
Value Range 0–5000 (0: Infinite time)
Default Value 800,400,800,4000
BELL_CORE_PATTERN3_TIMING
Value Format Comma-separated Integer
Description Specifies the cadence, in milliseconds, of pattern ID 3, described in the
LSSGR, GR-506-CORE, "Signaling for Analog Interfaces" section 14,
using 6 whole numbers separated by commas.
Value Range 0–5000 (0: Infinite time)
Default Value 400,200,400,200,800,4000
BELL_CORE_PATTERN4_TIMING
Value Format Comma-separated Integer
166 Administrator Guide Document Version 2010.03.15
4.5.2 Tone Settings