2.11 Frame Ground Connection

2.11 Frame Ground Connection

IMPORTANT

Connect the frame of the main unit to ground. The grounding plug of the AC cable provides some protection from external noise and lightning strikes, but it may not be enough to fully protect the unit. A permanent connection between ground and the ground terminal of the unit must be made.

1.Loosen the screw.

2.Insert a grounding wire (user-supplied).

Note

Green-and-yellow insulation is required, and the cross-sectional area of the conductor must be more than 0.75 mm2 or 18 AWG.

3.Tighten the screw.

4.Connect the grounding wire to ground.

KX-TVA50

Screw

Grounding wire

To ground

KX-TVA200

Screw

Grounding wire

To ground

Note

Be sure to comply with applicable local regulations (e.g., laws, guidelines).

Proper connection to ground is very important to protect the unit from external noise, and can reduce the risk of electrocution in the event of a lightening strike.

Document Version 3.0 2010/06