5.2.3 PBX Parameters

5.2.3 PBX Parameters

The following items can be programmed using KX-TVA Maintenance Console under System Parameters by selecting the Parameters tab.

PBX Environment

PBX Type

Specifies the type of PBX which is connected to the VPS.

Integration Mode

Select Inband. If PBX type is set to the Panasonic KX-T series, the inband signaling parameters are set automatically and should not be altered.

SEQUENCE CODES

D

F

R

T

X

,

;

0-9, , #

Disconnect

Hookswitch Flash

Ring Detection

Dial Tone Detection

Dial Extension

Dialing Pause (default 1 s)

Dialing Pause (default 3 s)

DTMF Tones

Maximum Extension Number Length

Specifies the maximum number of digits that the connected PBX recognizes as an extension number.

Extension Number of VPS Port

Specifies the extension number for each VPS port on the connected PBX.

Note

Extension numbers of the VPS ports will automatically be assigned when the PBX type has been changed.

Operator Transfer Sequence

Tells the VPS how to transfer a call to the operator.

Example: FTX [hookswitch flashdial tonedial (operator) extn.]

Extension Transfer Sequence

Tells the VPS how to transfer a call to an extension. Example: FTX [hookswitch flashdial tonedial extn.]

Alternate Extension Transfer Sequence

Tells the VPS how to transfer a call to an extension that belongs to the Alternate Extension Group. This is useful for extensions that need a special transfer procedure (i.e., blind transfer) such as modem extensions. Example: FTXD [hookswitch flashdial tonedial extn.hang up]

Reconnect Sequence on Busy

Tells the VPS how to return to the caller if the called extension is busy. PBXs differ in how they handle this function. Test from an SLT to determine the sequence.