108
CONTROLLING THE CONTACT OUTPUTIt is possible to designate the output port, output type (open/close), and output time of the control pulse which is
supplied from the contact output port of the encoder.
■Format
■Response
■Important Notice
•The output time will be invalid when "momentary" is selected for the output mode.
■Item List
Item Parameter name Parameter value Description
Output port PIO 1 - 4 Designate the output port
Output mode OUT latch Supply the pulse from the output port dur-
ing designated output time
momentary Trigger output will be supplied for around
300 seconds
Output type TYPE open, close Designate the output type
Output time TIME 1 - 1 800 Designate the output time (unit x 100 ms)
Valid only when "latch" is selected for the
output mode.
0Retain the designated status