108
CONTROLLING THE CONTACT OUTPUT
It is possible to designate the output port, output type (open/close), and output time of the control pulse which is
supplied from the contact output port of the encoder.
Format
Response
Important Notice
The output time will be invalid when "momentary" is selected for the output mode.
Item List
Item Parameter name Parameter value Description
Output port PIO 1 - 4 Designate the output port
Output mode OUT latch Supply the pulse from the output port dur-
ing designated output time
momentary Trigger output will be supplied for around
300 seconds
Output type TYPE open, close Designate the output type
Output time TIME 1 - 1 800 Designate the output time (unit x 100 ms)
Valid only when "latch" is selected for the
output mode.
0Retain the designated status
HTTP /1.1 200 OK CR
LF
Cache-Control: no-cache CR
LF
Content-Type: text/plain CR
LF
Content-Length: XX CR
LF (XX: Display the octet number of the Message-Body decimally)
CR
LF
http://(IP address of the encoder)/cgi-bin/pioctrl.cgi?com=set_pio&PIO=(parameter value)&OUT=(parameter
value)&TYPE=(parameter value)&TIME=(parameter value)&submit=ACTION
HOW TO USE THE CGI COMMANDS