54
RS-485 DATA PORT page
Perform the settings to send and receive serial data
duplex. The setting values should be the same for both
devices.
Notes
Packets will be sent to a network when either setting
of "WAITING DATA SIZE TO SEND PACKET" or
"WAITING TIMER TO SEND PACKET" is fulfilled.
When "PREFERENCE SETUP" is selected for
"DESTINATION SETUP", packets will be set to only
one destination.
The encoder cannot receive fragmented UDP
packets correctly.
Click the [SET] button to save the changed settings.
Otherwise, the changed settings will not be saved.
Item Descriptions

RS-485 DATAPORT SETUP

Perform the transmission settings of the encoder with
a device connected to the RS-485 data port of the
encoder.
These settings should be the same for both the
encoder and the device connected to the encoder.
BAUD RATE
Select a transmission speed for the RS-485 data port
from the following.
4 800 bps, 9 600 bps, 19 200 bps
The default setting is "9 600 bps".
DATA
Select "7 BIT" or "8 BIT".
The default setting is "8 BIT".
STOP BIT
Select "1 BIT" or "2 BIT".
The default setting is "1 BIT".
PARITY
Select from "NONE", "ODD" or "EVEN".
The default setting is "NONE".
WAITING DATA SIZE TO SEND PACKET (1 - 1024
byte)
Enter a desired data length of serial data the RS-485
data port can receive at one time. The entered size
will be the maximum size of the packet to be sent to
the network. When the received serial data is bigger
than the entered size, the received data will be
divided into two or more packets and then sent to the
network.
1 to 1024 are available for "WAITING DATA SIZE TO
SEND PACKET" (1 byte step).
The default setting is "200".
WAITING TIMER TO SEND PACKET (10 - 1000ms)
Enter a desired waiting time (time from when the RS-
485 data port receives serial data to when it sends a
packet to the network).
1 to 1 000 (ms) are available for "WAITING TIMER
TO SEND PACKET" (10 ms intervals).
The default setting is "100".
SETTINGS MENUS OF THE ENCODER