Paradyne 8955, 8968, 8965, and 8985 Creating Line Profiles for Ports, Procedure, Field, Description

Models: 8955

1 50
Download 50 pages 39.39 Kb
Page 19
Image 19
Creating Line Profiles for Ports (8985)

3. Configuration Using the Web Interface

3. Click on Apply.

Creating Line Profiles for Ports (8985)

determine whether remote management is supported for Procedure

To create a line profile for SHDSL ports:

1.Click on Create New Profile. The SHDSL Profile Create screen appears.

2.Enter or select the following fields:

Field

Description

 

 

Profile Name

Specify a name for this line profile.

 

 

Max Rate

Enter a maximum rate from 192 to 2304 kbps.

 

 

Min Rate

Enter a minimum rate from 192 to 2304 kbps.

 

 

Mode

Select the regional setting supported, as specified by

 

ITU-T G.991.2:

 

Annex A

 

￿Annex B

 

Both

 

 

Remote Management

Select Enable or Disable from the drop-down list to

 

determine whether remote management is supported for

 

the network element this profile is assigned to.

 

 

Reference Clock

Select the timing source from the drop-down list:

 

System – Clocking is provided by the backplane. (The

 

backplane clock is configured on the Configuration -

 

￿System - Clocking screen.)

 

Local – Clocking is provided by an onboard oscillator.

 

 

Target Margin

Enter a target noise margin from 2–15 dBm, or None.

 

 

Interface

Select an interface from the drop-down list:

 

￿Wire Pair 1 – The profile applies to Wire Pair 1.

 

Wire Pair 2 – The profile applies to Wire Pair 2.

 

Select Wire Pair 1 if this profile is to be used for ports that

 

use only one wire pair.

 

 

3. Click on Apply.

8900-A2-GB20-30

June 2004

3-7

Page 19