Paradyne and 8985, 8968, 8965 Creating Alarm Threshold Profiles for Model, 3-10, Procedure, Field

Models: 8955

1 50
Download 50 pages 39.39 Kb
Page 22
Image 22
Creating Alarm Threshold Profiles for Model 8985

3. Configuration Using the Web Interface

Creating Alarm Threshold Profiles for Model 8985

3-10 Procedure

To create an alarm threshold profile for an SHDSL line card:

1.Click on Create New Profile. The Alarm Threshold Profile Create screen appears.

2.Enter or select the following fields:

Field

Description

 

 

Profile Name

Specify a name for this alarm profile.

 

 

Loop Attenuation Threshold

Specify a loop attenuation alarm threshold of 0–127 dB.

 

An SNMP Loop Attenuation crossing trap message and a

 

TL1 autonomous message may be sent if the current loop

 

attenuation reaches or exceeds this threshold. A Loop

 

Attenuation alarm will also be declared when the current

 

Loop Attenuation exceeds this value. A value of 0 disables

 

event notifications for the condition.

 

 

SNR Margin

Specify an SNR Margin alarm threshold of 0–15 dB. An

 

SNMP Margin crossing trap message and a TL1

 

autonomous message may be sent if the current SNR

 

Margin reaches or drops below this threshold. An SNR

 

Margin alarm will also be declared when the current SNR

 

Margin has dropped below this value. A value of 0

 

disables event notifications for the condition.

 

 

Errored Seconds

Specify an ES threshold of 0–900 seconds. An SNMP ES

 

trap message and a TL1 autonomous message may be

 

sent if the number of ES events in a 15-minute interval

 

equals or exceeds the selected value. At most one SNMP

 

and one TL1 notification will be sent per interval per

 

device. A value of 0 disables event notifications for the

 

condition.

 

 

Severely-Errored Seconds

Specify an SES threshold of 0–900 seconds. An SNMP

 

SES trap message and a TL1 autonomous message may

 

be sent if the number of SES events in a 15-minute

 

interval equals or exceeds the selected value. At most one

 

SNMP and one TL1 notification will be sent per interval

 

per device. A value of 0 disables event notifications for the

 

condition.

 

 

Code Violations

Specify a Code Violations threshold of 0–900 seconds. An

 

SNMP code violations trap message and a TL1

 

autonomous message may be sent if the number of Code

 

Violations in a 15-minute interval equals or exceeds this

 

threshold. At most one SNMP and one TL1 notification will

 

be sent per interval per device. A value of 0 disables event

 

notifications for the condition.

 

 

3-10

June 2004

8900-A2-GB20-30

Page 22
Image 22
Paradyne and 8985, 8968, 8965, 8955 manual Creating Alarm Threshold Profiles for Model, 3-10, Procedure, Field, Description