Paradyne and 8985 Adding a Slot-to-Slot Cross Connection, 3-14, Procedure, Field, Description

Models: 8955

1 50
Download 50 pages 39.39 Kb
Page 26
Image 26
Adding a Slot-to-Slot Cross Connection

3. Configuration Using the Web Interface

Adding a Slot-to-Slot Cross Connection

3-14 Procedure

To create a range of VCCs between specified slots and the SCP card:

1.On the Configuration - Cross Connect screen, click on Create Cross Connect by Slot. The Configuration - Cross Connect - Slot screen appears.

2.Enter or select the following fields:

Field

Description

 

 

Start Slot

Select from the drop-down list the first slot in a range to

 

have connections established to the SCP card.

 

 

End Slot

Select from the drop-down list the last slot in a range to

 

have connections established to the SCP card. It may be

 

the same as the Start Slot.

 

 

Start Port

Select from the drop-down list the first port in a range to

 

have a connection established to the SCP card. The

 

range of ports will be applied to all slots selected.

 

 

End Port

Select from the drop-down list the last port in a range to

 

have a connection established to the SCP card. It may be

 

the same as the Start Port. The range of ports will be

 

applied to all slots selected.

 

 

Slot VPI

Enter the VPI of this circuit.

 

 

Slot VCI

Enter the VCI of this circuit.

 

 

Segment End Point (Slot)

Select True or False from the drop-down list to signify

 

whether this connection is the segment endpoint. This

 

field determines if the port card will function as an

 

endpoint for ATM OAM loopbacks. If False, the port card

 

will loop back a cell only if its location ID matches the

 

preconfigured location ID. (See Configuring ATM Ports on

 

page 3-16.) All other loopback cells are passed to the

 

next segment.

 

 

SCP VPI

Enter the VPI of this range of VCCs.

 

 

SCP Start VCI

Enter the first VCI of this range of VCCs.

 

 

Segment End Point

Select True or False from the drop-down list to signify

 

whether this connection is the segment endpoint. This

 

field determines if the port card will function as an

 

endpoint for ATM OAM loopbacks. If False, the port card

 

will loop back a cell only if its location ID matches the

 

preconfigured location ID. (See Configuring ATM Ports on

 

page 3-16.)All other loopback cells are passed to the

 

next segment.

 

 

Upstream Profile

Select a profile for upstream traffic.

 

 

Downstream Profile

Select a profile for downstream traffic.

 

 

3-14

June 2004

8900-A2-GB20-30

Page 26
Image 26
Paradyne and 8985, 8968, 8965, 8955 manual Adding a Slot-to-Slot Cross Connection, 3-14, Procedure, Field, Description