Paradyne 8955, 8968, 8965, and 8985 manual 3-11, Field, Description, Click on Apply

Models: 8955

1 50
Download 50 pages 39.39 Kb
Page 23
Image 23
3-11

3. Configuration Using the Web Interface

Field

Description

 

 

Loss of Sync Word Seconds

Specify a Loss of Sync Word Seconds threshold of 0–900

 

seconds. An SNMP LOSWS trap message and a TL1

 

autonomous message may be sent if the number of

 

LOSWS in a 15-minute interval equals or exceeds this

 

threshold. At most one SNMP and one TL1 notification will

 

be sent per interval per device. A value of 0 disables event

 

notifications for the condition.

 

 

Unavailable Seconds

Specify an Unavailable Seconds threshold of 0–900

 

seconds. An SNMP UAS trap message and a TL1

 

autonomous message may be sent if the number of UAS

 

events in a 15-minute interval equals or exceeds the

 

selected value. At most one SNMP and one TL1

 

notification will be sent per interval per device. A value of

 

0 disables event notifications for the condition.

 

 

3. Click on Apply.