Messages and Troubleshooting

Table 6-2. Troubleshooting (2 of 2)

Symptom

Possible Cause

Solutions

Not receiving data.

H The network or data port

H Check network and data port

 

cables are not

cables.

 

connected (check front

H Run Loopback tests. Refer to

 

panel LEDs for more

 

Chapter 5, Testing.

 

information).

 

 

 

H A test is being executed

H Stop the test or wait for the test to

 

on the unit (check the

end.

 

TEST LED on the front

 

 

panel).

 

 

H The far-end unit is

H Make sure the far-end device is

 

off-line.

on.

 

H The far-end unit is

H Stop the far-end test.

 

running a test.

 

 

H An alarm condition exists

H Check the far-end Health and

 

in the far-end unit.

Status messages.

 

 

 

 

 

Power-Up Self-Test

The unit has detected an

H Reset the unit and try again.

fails. Only Power

internal hardware failure.

H Contact your service

and Alarm LEDs are

 

 

representative.

on after power-up.

 

 

 

 

 

 