Configuration Option Tables

Table A-5. Telnet Session Options

Telnet Session

Possible Settings: Enable, Disable

Default Setting: Enable

Specifies if the Termination Unit will respond to a Telnet session request from a Telnet client on an interconnected IP network.

Enable ± Allows Telnet sessions between the unit and a Telnet client.

Disable ± No Telnet sessions allowed.

Telnet Login Required

Possible Settings: Enable, Disable

Default Setting: Disable

Specifies whether a user ID and password are required to access to the ATI through a Telnet session. Login IDs are created with a password and access level. Refer to Creating a Login in Chapter 7, Security.

Enable ± Security is enabled. When access is attempted via Telnet, the user is prompted for a Login ID and password.

Disable ± No Login required for a Telnet session.

Session Access Level

Possible Settings: Administrator, Operator

Default Setting: Administrator

The Telnet session access level is interrelated with the access level of the Login ID. Refer to ATI Access Levels in Chapter 7, Security for more information.

Administrator ± This is the higher access level, permitting full control of the 7984 Termination Unit. Access level is determined by the Login ID. If Telnet Login Required is disabled, the session access level is Administrator.

Operator ± This is the lower access level, permitting read-only access to status and configuration screens.

Inactivity Timeout

Possible Settings: Enable, Disable

Default Setting: Disable

Provides automatic logoff of a Telnet session.

Enable ± The Telnet session terminates automatically after the Disconnect Time. Set the Disconnect time (in minutes) after enabling Inactivity Timeout.

Disable ± A Telnet session will not be closed due to inactivity.

Disconnect Time (Minutes)

Possible Settings: 1 ± 60

Default Setting: 5

Number of minutes of user inactivity before a Telnet session terminates automatically. Time out is based on no keyboard activity.

HDisconnect Time (minutes) appears only when the Inactivity Timeout option is enabled.

1 to 60 ± The Telnet session is closed after the selected number of minutes.