Patton electronic manual System reset mode, DIP switch settings, Model 3088A

Models: 3088A

1 71
Download 71 pages 59.37 Kb
Page 22
Image 22
Model 3088A

Model 3088A Series Getting Started Guide

2 • Configuration

 

 

The three sets of DIP switches are externally accessible from the underside of the Model 3088A (see figure 4).

ON

 

 

 

 

 

 

S4

 

 

 

 

 

 

 

1

2

3

4

5

6

7

8

ON

 

 

 

 

 

 

S3

 

 

 

 

 

 

 

1

2

3

4

5

6

7

8

ON

 

 

 

 

 

 

S1

1

2

3

4

5

6

7

8

Model 3088A

Figure 4. Underside of Model 3088A showing location of DIP switches

The three sets of DIP switches on the underside of the Model 3088A are referred to as S1, S3 and S4. For basic configuration, use DIP switch S1. For testing the 3088A, use DIP switch S3. To configure the rate, use DIP switch S4. This figure shows the DIP switch orientation with respect to ON and OFF positions is consistent for all switches.

System reset mode

To enter system reset mode, turn the S1-1DIP switch to the ON position and power cycle the unit. For information on how to upgrade the software, refer to Chapter 6, “Software Upgrade” on page 49. For more information on applying factory default configuration to the 3088A, refer to Chapter 7, “Reset configuration to factory defaults” on page 51.

 

 

 

 

ON

 

 

 

 

 

 

 

 

1

 

 

 

ON

 

 

 

2

 

 

 

 

 

 

 

 

3

 

 

 

 

 

 

 

 

4

 

 

 

 

 

 

 

 

5

 

 

 

 

 

 

 

 

6

 

 

 

 

 

 

 

 

7

 

 

 

 

 

 

 

 

8

 

 

 

 

 

 

 

 

 

 

 

 

 

DIP switch settings

OFF

 

You can configure the 3088A by setting the DIP switches to the desired positions before you

 

power up the OnSite. If the DIP switches are set to anything other than all OFF or all ON, the OnSite will operate in DIP switch configuration mode. Once the device is powered up and operating in DIP switch config- uration mode, you cannot change configuration by any method until you power it down again.