SmartNode 4400 Series Getting Started Guide

3 • Hardware installation

 

 

Power cable retainer clip

IEC-320 connector

(2 places)

Grounding stud

Figure 11. IEC-320 connector and grounding stud locations

2.Install the grounding wire between the grounding stud (see figure 11) and the grounding source.

WARNING

WARNING

Mains Voltage: Do not open the case the when the power cord is attached. Line voltages are present within the power supply when the power cords are connected. The mains outlet that is utilized to power the device shall be within 10 feet (3 meters) of the device, shall be easily accessible, and pro- tected by a circuit breaker.

The Model SN4400 is not shipped with power cables. For AC powered units, ensure that the power cable used meets all applicable standards for the coun- try in which it is to be installed, and that it is connected to a wall outlet which has earth ground.

The router power supply automatically adjusts to accept an input voltage from 100 to 240 VAC(50/60 Hz).

IMPORTANT

Installing the power cables—AC units

This section describes installing the power cables into the IEC-320 connectors on the IpChannel Bank. Do not connect the remaining end of the power cables to the power outlet at this time. Do the following:

1.Install the power cable into an IEC-320 connector (see figure 11 on page 31). The AC mains socket outlet shall be within 1 foot (3 meters) of the equipment and shall be easily accessible.

Installing the IpChannel Bank

31

Page 31
Image 31
Patton electronic 4400 manual Installing the power cables-AC units