group HS module 3

output eq features

The HS output-section includes twelve output-equalizers occupying the upper portions of the eight GROUP sub-modules and the four MASTER sub- modules.

By using designated assignment switches, output eq’s can be fed by the eight AUXES or GROUPS,the four matrix masters or left, right,and mono mas- ters.Each eq features five-bands of equalization,making them ideal for feed- ing on-stage or in-ear monitors.

high frequency—HF

15dB boost and cut at 12kHz—shelving response.

high-mid frequency—HM

Selectable frequency range of 400Hz to 8 kHz.

The response is bell-shaped with a fixed Q of 1.5

15dB boost and cut.

mid frequency—MID

Selectable frequency range of 200Hz to 4kHz.

The response is bell-shaped with a fixed Q of 1.5

15dB boost and cut.

low-mid frequency—LM

Selectable frequency range of 100Hz to 2kHz.

The response is bell-shaped with a fixed Q of 1.5

15dB boost and cut.

low frequency—LF

Selectable frequency range of 20Hz to 400Hz.

The response is bell-shaped with a fixed Q of 1.5.

15dB boost and cut.