Pelco ES30PC, ES31PC manual To set the DIP switches

Models: ES31PC ES30PC

1 70
Download 70 pages 33.09 Kb
Page 10
Image 10
To set the DIP switches:

ESPRIT

AUX 2

ORANGE WIRE

AUX 2 COM

BLUE WIRE

AUX2 Schematic Drawing

USER

ACCESSORY

K1

OMRON G5V-1-DC12

D1

1N4005

AUX 2

AUX 2 COM

NOTE: CURRENT MUST NOT EXCEED 40 mA.

V1

32 VDC

7.Install mount; refer to the installation manual supplied with the mount for instructions.

8.Turn on the power. If the red LED lights, turn off the power and proceed to the next step. If the red LED does not light, refer to the Troubleshooting section.

9.Plug the male Esprit system connector, located on the bottom of the pan and tilt, into the female Esprit system connector located on the transformer module. Align the pan and tilt part number with the alignment label of the base and then attach the pan and tilt to the base with three 1/4-20 nuts and washers (supplied).

PART Manual background

NUMBER

MALE SYSTEM Manual backgroundManual background

CONNECTOR

FEMALE

SYSTEM

ALIGNMENTCONNECTOR

LABEL

10.Set the receiver address and system baud rate by configuring DIP switches SW1 and SW2.

NOTE: If you have a Coaxitron controller, you do not have to set the DIP switches. The Esprit will sense and automatically select settings from Coaxitron control signals in either standard or extended mode.

To set the DIP switches:

a.Remove the plug from the left cover of the pan and tilt. It is not necessary to remove the pan and tilt cover.

b.Set the baud rate (SW1) and receiver address (SW2). For switch settings refer to the labels located on top of the camera module or Tables A and B in the “Appendix” on page 63.

10