Pelco ES31PC, ES30PC manual Gain/Agc, Gain Limit

Models: ES31PC ES30PC

1 70
Download 70 pages 33.09 Kb
Page 37
Image 37
GAIN/AGC

GAIN/AGC

MAIN MENU

 

 

Camera Menu

 

 

 

Gain/AGC Menu

 

 

 

 

 

Backlight comp

Off

 

 

Gain Limit

27

<Camera>

 

 

<Line Sync>

 

 

Zoom limit

x- -

 

 

Exit

 

<Power Up>

 

 

Reset camera

 

 

 

 

 

<Wiper>

 

 

<Gain/AGC>

 

 

 

 

 

<Limit Stop>

 

 

<Auto iris>

 

 

 

 

 

<Alert>

 

 

Next

 

 

 

 

 

<Other>

 

 

Exit

 

 

 

 

 

ACK Alert

 

 

 

 

 

 

 

 

Exit

 

 

 

 

 

 

 

 

GAIN LIMIT

The gain limit sets the maximum level for the automatic gain control. Increasing the level will increase the signal level and increase the noise level of the picture.

To change the gain:

1.Program preset 95 (28). The main menu appears.

2.Position the cursor (>) beside Camera.

3.Press the Iris Open button to enter the Camera menu.

4.Position the cursor (>) beside Gain/AGC.

5.Press the Iris Open button to enter the Gain/AGC menu.

6.Position the cursor (>) beside Gain Limit.

7.Press the Iris Open button. The cursor moves to the right, beside the current gain level setting (a numeric value).

8.Move the joystick up or down to change the level.

9.SELECT: Press the Iris Open button on your keyboard to select your choice.

CANCEL: Press the Iris Close button if you do not want to change the setting.

C311M-N (6/06)