PRESSURIZED INTEGRATED OPTICS CARTRIDGE
The pressurized IOC houses an auto focus camera, lens, heater, and sensors in a
Sensors strategically placed inside the pressurized IOC continually monitor pressure, temperature, and relative humidity. If internal conditions reach unacceptable levels, an alert label appears on the screen describing the alert condition. Example: If pressure drops below 1 psig, LOW PRESSURE is displayed on the monitor.
The following conditions will trigger an alert:
CONDITION | ALERT LABEL |
|
|
1 psig | Low Pressure |
|
|
25 psig | High Pressure |
|
|
Low Temperature | |
|
|
60°C | High Temperature |
|
|
20% | High Relative Humidity |
|
|
ALERT LABEL CYCLE
The Esprit system continually checks internal environmental conditions every 60 seconds. An ALERT label appears on the monitor if conditions are beyond manufacturer set acceptable limits. The label will be repeatedly displayed until acknowledged by the system controller. Once acknowledged, alert behavior changes to the programmed acknowledge action. If the alert condition remains unacceptable after a period of time, the ALERT label will reappear on the monitor, restarting the alert label cycle. The cycle will continue until the alert condition is resolved.
ALERT LABEL
DISPLAYED ON
MONITOR
CYCLE REPEATS UNTIL | CONDITION IS RESOLVED |
ALERT CONDITION
NOT RESOLVED
REPEAT | USER DEFINED REFER | |
ALERT LABEL IS | ||
TO REPEAT IN THE | ||
DISPLAYED ON MONITOR | PROGRAMMING | |
UNTIL ACKNOWLEDGED | SECTION OF THIS | |
BY CONTROLLER | MANUAL | |
|
ACK ALERT
ALERT ACKNOWLEDGED
ACK ACT
ONCE ACKNOWLEDGED | USER DEFINED REFER | |
ALERT LABEL BEHAVIOR | TO ACK ACT IN THE | |
CHANGES TO THE ACTIVE | PROGRAMMING | |
SECTION OF THIS | ||
RESPONSE PROGRAMMED | ||
MANUAL | ||
FOR ACK ACT |
|
ALERT CONDITION
LABEL OFF
RESOLVED
ALERT RESET
The Alert Reset function clears alert conditions and removes the ALERT label. The system will automatically check internal environmental conditions 60 seconds after reset. If conditions remain beyond manufacturer set acceptable limits, the ALERT label will reappear on the screen indicating further corrective action is required.