Pelco manual Programming - ES30PCBW24/ES31PCBW24, Iris Open Enter, Iris Close Cancel, Presets

Models: ES31PC ES30PC

1 70
Download 70 pages 33.09 Kb
Page 20
Image 20
Programming – ES30PCBW24/ES31PCBW24

Programming – ES30PCBW24/ES31PCBW24

1.Access main menu (preset 95).

2.Make main menu selections.

Joystick: Move up or down to position cursor or to toggle between selections.

Iris Open: Enter.

Camera Menu

 

Iris Close: Cancel.

 

Backlight comp

Off

 

 

Zoom limit

x72

 

Reset camera

 

MAIN MENU

<Gain/AGC>

 

<Camera>

<Auto iris>

 

Next

 

<Line Sync>

 

Exit

 

<Power Up>

 

 

 

*<Wiper>

Line Sync Menu

 

<Limit Stop>

 

<Alert>

Line Sync

On

<Other>

Line Sync Phase

0

ACK Alert

Exit

 

Exit

 

 

 

PRESETS

Power-Up Menu

The following presets are

Power Up

Default

reserved for special functions.

Exit

 

Preset Function

1 Park

33Flip command

34Pan zero command

90-91

Manual limit stops

*Wiper Menu

92-93

Auto limit stops

Wiper Mode

Momentary

95

Select camera

Wiper Dwell <s>

2

 

programming menu

Wiper Time <m>

60

96

Stop a scan

Exit

 

97Random scanning

98Frame scanning

99Auto scanning

Gain/AGC Menu

 

Gain Limit

28

Exit

 

Auto Iris Menu

 

Auto-iris mode

Auto

Auto-iris level

91

Auto-iris peak

16

Exit

 

Next Menu

 

LowLight limit

2

Shutter speed

Auto

Auto focus mode

Auto

<IR Filter>

 

<Sharpness>

 

<White balance>

 

Prev

 

Exit

 

IR Filter Menu

 

IR Filter mode

Auto

Auto IR Level

Dusk

Exit

 

Sharpness Menu

Auto Sharpness

SharpnessOn

Exit

White Balance Menu

 

Auto white bal

On

R-Gain

182

B-Gain

182

Exit

 

*ES31PC only

NOTE: For American Dynamics controllers with only 32 presets, set switch SW1-5 on the Esprit system to the ON position. When SW1-5 is ON, preset

99 becomes 32

98 becomes 31

97 becomes 30

96 becomes 29

95 becomes 28

94 becomes 27

93 becomes 26

92 becomes 25

91 becomes 24

90 becomes 23

89 becomes 22

88 becomes 21

If the limit stops are turned off (refer to the Limit Stops section), presets 23-26 can be used as regular presets.

Limit Stop Menu

Limit Stops

 

Off

Set Man Limits

 

 

Clear Man Limits

 

Set Scan Limits

 

 

Clear Scan Limits

 

Exit

 

 

Alert Menu

Repeat

 

Constant

Disp Pos

 

Top Right

ACK Act

 

Always On

<Current Reading>

 

Alert Reset

 

 

Exit

 

 

Other Menu

Proportional pan

On

Park time minutes

0

Scan Speed deg/s

25

Pattern Length

 

1.5 min

Spd Profile

50 MPH Wind

<Zone Blank>

 

 

<Az/El/Direction> Exit

IOC Internal Reading

Temperature

37 C

 

98 F

Dewpoint

08 C

 

46 F

Pressure

10.30 psig

Refresh

0.71 bar

 

Exit

 

For detailed instructions, refer to the following sections.

Menu items are listed alphabetically.

Zone Blank Menu

Video Blank Zone

1 Off

 

2 Off

 

3 Off

 

4 Off

 

5 Off

 

6 Off

 

7 Off

Exit

8 Off

 

Az/El/Direction

 

Set Azimuth Zero

0

Az/El

Left

Az/El Line

10

Direction

Right

Direction Line

10

Zoom

Center

Zoom Line

10

Disp Duration

2

Exit

 

20

C311M-N (6/06)

Page 20
Image 20