120
Serial Port Profiles
Email Alert Tab Field DescriptionsEmail notification can be set at the Server and/or serial port levels. You can set unique email
notifications for each serial port because the person who administers the IOLAN might not be the
same person who administers the serial device(s) attached to the IOLAN port. Therefore, email
notification can be sent to the proper person(s) responsible for the hardware.
The following event triggers an email notification on the Serial Port for the specified Level:
zDSR signal loss, Warning Level
zI/O alerts, Critical Level
Configure the following parameters:
Enable Line
Termination Used with EIA-422 and EIA-485 on SDS 8-port and 16-port rack mount
IOLAN models, specifies whether or not the line is terminated; use this option
when the serial port is connected to a device at the end of the serial network.
Default: Disabled
Enable Port Email
Alert
Enable/disable email alert settings for this serial port.
Default: Disabled
Use System Email
Alert Settings
Determines whether you want the Serial Port to inherit the Email Alert settings
from the System Email Alert configuration. If this is enabled, System and
Serial Port notification events will have the same Email Alert setting.
Default: Enabled
Level Choose the event level that triggers an email notification.
Data Options: Emergency, Alert, Critical, Error, Warning, Notice, Info, Debug
Default: Emergency
Use System Setting By default, the fields are populated with the "global email" parameters. If you
wish to override a field you must uncheck this field.
To An email address or list of email addresses that will receive the email
notification.
Subject A text string, which can contain spaces, that will display in the Subject field of
the email notification.