Hardware and Connectivity 46
Powering up your IOLAN
zIOLAN I/O models with Analog I/O for setting Voltage/Current.
See Appendix E, Setting Jumpers to see how to set the jumpers for your IOLAN desktop model.
Medical Unit ModelsTo power up the medical unit IOLAN, perform the following steps:
1. You can attach the multi-function wall plate included with your medical unit IOLAN to the wall,
then mount the IOLAN on the wall plate. Alternatively, you can mount the IOLAN on a tabletop
or any suitable horizontal surface. See the IOLAN MDC Hardware Installation Guide for more
information on how to mount the medical unit IOLAN.
2. Plug a power cable into the left side (power/Ethernet panel) of the IOLAN unit and then into the
electrical outlet.
3. Power on the IOLAN unit using the Power ON/OFF switch.
4. You will see the LEDs blink for several seconds and then remain a solid green, indicating that it
is ready to configure/use.
Terminal Block ModelsPerform the following steps to power up the unit:
1. Ensure power is NOT applied to the wires prior to connection.
2. On each end wire, remove the insulation from the copper wire 5 mm (3/16 of an inch).
3. Loosen the left screw on the top of the terminal connector block, then insert your positive (+)
wire into the left terminal and screw it down tight. Loosen the right screw on the top of the
terminal connector block, then insert your negative (-) wire into the right terminal and screw it
down tight.
4. Plug the power supply into the electrical outlet.
5. A solid green LED indicates the unit is powered up.
For I/O models, you should set the IOLAN jumpers for Digital I/O (see Digital I/O Module ) or
Analog Input (Analog Input Module ) channels.
Note: For I/O models the Terminal Block is plugable.