Diagnostic Testing Under Windows 3.x 6-5
The main window of the diagnostic program is displayed.
3 From the Test menu, select Echo Server, and then click Start.
A message confirms that your PC is now set up as an echo server.
Starting the Group 3 Test
Follow these steps to run the Group 3 test on the 3C509B NIC:
1 Start the Configuration and Diagnostic Program on the PC
in which the NIC to be tested is installed.
2 From the Test menu, select Test Setup.
3 Enable the Group 3 test. Select OK and press Enter.
4 Go to the Run Tests dialog box to start the tests.
5 After the test is completed:
aExit the program on the echo server.
bExit the Configuration and Diagnostic Program.
Table 6-1 Diagnostic Programs
Diagnostic
Program Name NIC Installed
in the Echo Server
3C503.EXE EtherLink II® or II TP, EtherLink II/16 or II/16 TP
3C505.EXE EtherLink Plus®
3C507.EXE EtherLink 16 or EtherLink 16 TP
3C508CFG.EXE 3Com Red
3C5X9CFG.EXE EtherLink III family
3C523.EXE EtherLink/MC
3C523TP.EXE EtherLink/MC TP
3C527.EXE EtherLink/MC 32
3C59XCFG.EXE EtherLink III EISA/PCI bus master family (including Fast
EtherLink NIC running at 10 Mbps)
3C90XCFG.EXE EtherLink XL and Fast EtherLink XL family of NICs
running at 10 Mbps