Diagnostic Testing Under Windows 3.x

6-5

Table 6-1Diagnostic Programs

 

 

 

 

Diagnostic

NIC Installed

 

Program Name

in the Echo Server

 

 

 

 

3C503.EXE

EtherLink II® or II TP, EtherLink II/16 or II/16 TP

 

3C505.EXE

EtherLink Plus®

 

3C507.EXE

EtherLink 16 or EtherLink 16 TP

 

3C508CFG.EXE

3Com Red

 

3C5X9CFG.EXE

EtherLink III family

 

3C523.EXE

EtherLink/MC

 

3C523TP.EXE

EtherLink/MC TP

 

3C527.EXE

EtherLink/MC 32

 

3C59XCFG.EXE

EtherLink III EISA/PCI bus master family (including Fast

 

EtherLink NIC running at 10 Mbps)

 

3C90XCFG.EXE

EtherLink XL and Fast EtherLink XL family of NICs

 

 

running at 10 Mbps

 

 

 

 

The main window of the diagnostic program is displayed.

3From the Test menu, select Echo Server, and then click Start. A message confirms that your PC is now set up as an echo server.

Starting the Group 3 Test

Follow these steps to run the Group 3 test on the 3C509B NIC:

1Start the Configuration and Diagnostic Program on the PC in which the NIC to be tested is installed.

2From the Test menu, select Test Setup.

3Enable the Group 3 test. Select OK and press Enter.

4Go to the Run Tests dialog box to start the tests.

5After the test is completed:

a Exit the program on the echo server.

b Exit the Configuration and Diagnostic Program.

Page 79
Image 79