2.4.6Right Manual Top-Off (Split Vat Only):

Solstice I12+ Cooking Computer for ROV Fryers

Pitco P/N 60149517 & 60149518

2.4.6Right Manual Top-Off (Split Vat Only):

While in the advanced oil handling menu, press product key [5].

Display shows 3Control Filter Lockout (CFL):3.1Filter Soon:.

Press and hold product key [5] to manually add fresh oil to

Display will show 3.2Filter Now:Manual background while is held down.

Release product key [6] to stop adding fresh oil.

Press

the menu or select a product key [L-5] to

3Control Filter Lockout (CFL):

This computer includes the Cook Count-based Control Filter Lockout (CFL) function which enforces operator compliance with regularly scheduled filtering based on the number of cooks performed since the last filter.

Performing any automated oil filter operation will reset the cook counter. Also, any manual operation that includes the opening of the drain valve for 20 seconds or more will also reset the cook counter. The cook counter may be reset at any time, where the computer does not have to be in a Filter Soon or Filter Now state.

To check the current remaining cooks available before Filter Lockout, press the Manual background key until

the Cooks Remaining message Manual background is shown. Press the Manual background key again to show

the maximum number of cooks allowed – Manual background.

3.1Filter Soon:

Filter Soon message Manual background will show when the number of cooks since the last filter

operation is greater than the Cook Counts Allowed value (section 10.6). It is suggested to perform a filter operation when business levels permit.

The Manual background message will not be viewable if there are active cook timers.

Additional cooks are allowed when in Filter Soon state.

3.2Filter Now:

Filter Lockout messages Manual backgroundManual background or Manual background will show on the

displays when the number of cooks since the last filter operation is equal to the sum of the Cook Counts Allowed value and the Cook Counts Deferred value (section 10.7). It is required to perform a filter operation at this time.

The Manual background message will display when the final allowed cook has been completed. Perform the required filtering when this cook completes.

When in the Filter Lockout state, cooks are no longer allowed and product key presses are ignored.