Pitco Frialator 60149517 To Enter Programming Level 3 for the Technician, Melt Cycle ON Time

Models: 60149517 60149518

1 44
Download 44 pages 11.83 Kb
Page 23
Image 23
8To Enter Programming Level 3 (for the Technician):

Solstice I12+ Cooking Computer for ROV Fryers

Pitco P/N 60149517 & 60149518

8To Enter Programming Level 3 (for the Technician):

With no cook timers running, displays will show one of the following displays:

Press be

,

, or

The left display will show

.

8.1Offset the Temperature Display: . The right display will

Enter password

Level 3 Password

 

using the product keys as a numeric keypad for entry.

Display will show 8.2Melt Cycle ON Time:8.3Minimum ON and OFF Cycle Time:Manual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual background

. Product key indicators will illuminate

to prompt operator to select a key. This section details parameters that may be changed in Level 3 programming.

8.1Offset the Temperature Display:

This adjustment allows the displayed temperature value to be offset to reflect the true center vat temperature while reading the probe tip temperature. Default value is zero. With zero value set, displayed values are the probe temperature.

With display showing

press product key 1.

Display shows [OFF nn F] [DEGREES], where “nn” is the value of the adjustment.

Negative values are preceded with a minus sign.

To change this value, use the product keys for numeric entry of a new value.

Press

Use the product

selection, press

8.2Melt Cycle ON Time:

Display will show [POSITIVE] [DEGREES].

choices (Positive or Negative value). After

Display returns to

.

With display showing

press product key 2.

Display shows [MLTON :nn] [MELT ON], where “nn” is the value, in seconds, of time for a melt cycle heat pulse.

To change this value, use the product keys for numeric entry of a new value.

Press

Display returns to

.

8.3Minimum ON and OFF Cycle Time:

With display showing

press product key 3.

Display shows [MIN ON:nn] [MIN ON], where “nn” is the value, in seconds, of time for minimum heat pulse period.

To change this value, use the product keys for numeric entry of a new value, then press

seconds,

value.Press

Display shows [MIN OFF:nn] [MIN OFF], where “nn” is the value, in

heat off period. Use the product keys for numeric entry of a new

Display now shows

.

Page 23 of 44

L22-378 Rev 3

Page 23
Image 23
Pitco Frialator 60149517, 60149518 manual To Enter Programming Level 3 for the Technician, Offset the Temperature Display