8.8.3Heat Demand Profile:

Solstice I12+ Cooking Computer for ROV Fryers Pitco P/N 60149517 & 60149518

8.8.3Heat Demand Profile:

With display showing

, press product key 3. Display will show

[xxxxxxx] [HEAT DEM], where xxxxxxx may be one of 5 heat control profiles listed below.

1.[GENERIC 1] for gas fired fryer appliance.

2.[GENERIC 2] for electric fryer appliances, and model SGH50.

3.[T-STAT] control operates as a mechanical thermostat for general applications on gas or electric fryers. This setting offers the quickest possible recovery times at the expense of temperature overshoot suppression.

4.[ROV1] for use with SSHLV type models only.

5.[ROV2] for use with SELV models only. This is the factory default.

Use product key [0] change value, then press

.

8.8.4Shake Alarm Duration:

choice Display returns to

With display showing

, press product key 4. Display will show

[SH-DUR:nn] [DURATION], where “nn” is the time in seconds

product keys for numeric entry of desired value, then press

returns to

.

will sound. Use

ve choice. Display

8.8.5Hold Alarm Duration:

With the display showing

, press product key 5. Display will

show [HD-DUR:nn] [DURATION], where “nn” is the time in

Use product keys for numeric entry of desired value, then press

Display returns to

.

8.8.6Cancel Duration:

will sound.

choice.

With the display showing

, press product key 6. Display will

show [CANCEL:nn] [DELAY] , where “nn” is the time in seconds the operators must press a cancel a cook. Use product keys for numeric entry of desired value, then press

choice. Display returns to

. Default value is

8.8.7Configuration Value:

With display showing

, press product key 7. Display will show

[CFG hhhh], where “hhhh” is a hexadecimal checksum of the configuration memory contained

in the controller.

any part of the setup of this control will change the check

sum value. Press

will return to

.

Page 27 of 44