Recovery Times:

Solstice I12+ Cooking Computer for ROV Fryers

 

Pitco P/N 60149517 & 60149518

 

8.4

Recovery Times:

 

This controller maintains a record of heat up times for the appliance. A poorly running

 

 

appliance will have increased recovery times stored in this display. There is no

 

 

selection done here, just the display of recovery time values.

 

With display showing

, press the product key [0].

Display will show

.

Press product key 4; display will show [RECOVERY] [TEST].

Press the product key [0]. Display will show [FCTY nnn][RECOVERY], where nnn is the factory recovery value.

Press the product key [0]. Display will show [OLD nnn][RECOVERY], where nnn is the factory recovery value.

After recording these values,

Manual background .

Display will again return to