11Other Displays:

Solstice I12+ Cooking Computer for ROV Fryers

Pitco P/N 60149517 & 60149518

11Other Displays:

Open probe detection is standard on all Pitco controls. If probe is detected open, normal heating and cooking activities are suspended.

This display warns operators that the vat temperature has exceeded set temperature by +40°F (+22°C), or an absolute maximum of 410°F (210°C). The alarm will also sound. This display does not show the status of the mechanical high limit switch.

This message indicates that the drain valve has been opened, the vat is assumed to be empty by the controller. Normal heat control activities are suspended. Display will show an alternating message [DRAINING] [TURN OFF]. To restore to normal operation, close the drain value. Display will show [TURN OFF] [TURN OFF].

Turn controller off, and refill the vat. Continue with normal operations at section 1.

This message indicates that the heating system failed to respond. Typically, the high temperature limit switch has tripped and is in need of resetting. In the case on gas fired appliances, this message will display if the pilot fails to light or is detected marginal by the ignition module.

This message indicates a shorted probe. If probe is detected as a short circuit, normal heating and cooking activities are suspended.

This message indicates the computer has lost communication with the autofilter control board and oil management operations are suspended. Normal cooking activities are unaffected.