Pitco Frialator 60149517 manual Fresh Oil Supply Monitoring, JIB Oil Remaining, JIB Check/Error

Models: 60149517 60149518

1 44
Download 44 pages 11.83 Kb
Page 15
Image 15
4Fresh Oil Supply Monitoring

Solstice I12+ Cooking Computer for ROV Fryers

Pitco P/N 60149517 & 60149518

4Fresh Oil Supply Monitoring

This computer monitors the Jug-in-Box (JIB) fresh oil supply for oil remaining estimation and oil supply problems. The computer will monitor utilization of the JIB from on-demand, manual top-offs, automatic top-offs, and top-off events from other fryers in the battery.

4.1JIB Oil Remaining:

Low JIB message 4.1JIB Oil Remaining: will show and toggle with the current fryer state when the available fresh oil has dropped below the Low JIB configuration value (section 10.11.3).

Replace JIB message 4.2JIB Check/Error: will show and toggle with the current fryer state when

the available fresh oil has depleted. The operator at this time should replace the JIB with a new, full supply.

It is not recommended to replace JIB with a less-than-full supply.

To reset the JIB Oil Remaining monitor once the supply has been replaced:

is displayed.

Press product key [6] (YES) to reset the fresh oil supply to the Max JIB configuration value (section 10.11.2).

Note: Only one cooking computer in a fryer battery needs to have the oil remaining monitor enabled (section 10.11.1).

4.2JIB Check/Error:

For fryer configurations with the auto top-off option, the JIB error monitor displays the error

message Manual backgroundManual background when an auto top-off event has occurred three

times within 15 minutes for a single frypot. This message indicates to the operator that a JIB or its hose has been installed improperly, the JIB has been emptied and not replaced, or there is some other fault condition.

Check the JIB and resolve any fault conditions. Press any cook key to clear the Check JIB message.

When the Check JIB message is displayed, auto top-off for that frypot is temporarily disabled until the message is cleared and acknowledged.

Page 15 of 44

L22-378 Rev 3

Page 15
Image 15
Pitco Frialator 60149517, 60149518 manual Fresh Oil Supply Monitoring, JIB Oil Remaining, JIB Check/Error