Solstice I12+ Cooking Computer for ROV Fryers
Pitco P/N 60149517 & 60149518
10.3Polish Time:
This adjustment controls the oil cycle time for filter operation POLISH selected to allow oil to make multiple passes through the filter pan.
With display showing , press product
Display shows , where m:ss the vat will polish.
To change this value, use the product keys for numeric entry value. Acceptable entry range is 00:00 to 99:59.
Press | save entry. Display returns to |
10.4Fill Time:
|
This adjustment controls the vat fill time for
and return lines cleared of oil. Factory default: Full – 1:15, Split – 0:45
With display showing | , press product | | |
| Display shows | , where m:ss |
|
| the vat will fill. |
|
|
| To change this value, use the product keys for numeric entry |
| |
| value. Acceptable entry range is 0:30 to 4:00. |
|
|
Press | save entry. Display returns to |
10.5Filter Temperature:
This adjustment selects the minimum oil temperature allowed for initiated. Manual filter operations are unaffected by this value.
With display showing , press product
Display shows , where nnn minimum oil temperature autofilter operations can be where X is F (Fahrenheit) or C (Celsius).
To change this value, use the product keys for numeric entry value.
Press | save entry. Display returns to |
|
Page 33 of 44 |